MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/pep.0b013e31824c94ca

Медицинская библиотека · Pediatric physical therapy : the official publication of the Section on Pediatrics of the American Physical Therapy Association · 2012

Concurrent validity and reliability of the pediatric evaluation of disability inventory-computer adaptive test mobility domain.

Dumas Helene M, Fragala-Pinkham Maria A

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод в очереди

Аннотация

PURPOSE: To examine concurrent validity, item-specific reliability, and score distributions of the new Pediatric Evaluation of Disability Inventory-Computer Adaptive Test (PEDI-CAT) Mobility domain with the original PEDI Functional Skills (FS) Mobility Scale.

METHODS

Thirty-five parents of children with neurodevelopmental disabilities completed the PEDI-CAT on a computer and the paper PEDI FS via interview.

RESULTS

Strength of association between the PEDI-CAT Mobility domain and PEDI FS Mobility Scale scores was good to excellent (r = 0.82; P < .001). Intraclass correlation coefficients ranged from .3390 to 1.000, and agreement ranged from 60% to 100% for 8 specific items. No child had the minimum score on either test, whereas 9 children (26%) had a maximum score on the PEDI FS Mobility Scale.

CONCLUSIONS

This study provides evidence for potential users that the concurrent validity, reliability, and score distribution for the PEDI-CAT Mobility domain are adequate for use with children with varied diagnoses and throughout the pediatric age span.

Для цитирования: Dumas Helene M, Fragala-Pinkham Maria A. Concurrent validity and reliability of the pediatric evaluation of disability inventory-computer adaptive test mobility domain.. Pediatric physical therapy : the official publication of the Section on Pediatrics of the American Physical Therapy Association. 2012. DOI: 10.1097/pep.0b013e31824c94ca.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление