MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clgc.2018.05.014

Медицинская библиотека · Clinical genitourinary cancer · 2018

Comparison Between 64Cu-PSMA-617 PET/CT and 18F-Choline PET/CT Imaging in Early Diagnosis of Prostate Cancer Biochemical Recurrence.

Cantiello Francesco, Crocerossa Fabio, Russo Giorgio Ivan, Gangemi Vincenzo, Ferro Matteo, Vartolomei Mihai Dorin, Lucarelli Giuseppe, Mirabelli Maria, Scafuro Chiara, Ucciero Giuseppe, De Cobelli Ottavio, Morgia Giuseppe, Damiano Rocco, Cascini Giuseppe Lucio

Сравнительное исследованиеСтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

PURPOSE: To evaluate the diagnostic performance of 64Cu-PSMA-617 positron emission tomography (PET) with computed tomography (CT) for restaging prostate cancer after biochemical recurrence (BCR) and to compare it with 18F-choline PET/CT in a per-patient analysis.

PATIENTS AND

METHODS

An observational study was performed of 43 patients with BCR after laparoscopic radical prostatectomy who underwent 64Cu-PSMA-617 PET/CT and subsequently 18F-choline PET/CT for restaging. The detection rates (DR) of 64Cu-PSMA-617 PET/CT and of 18F-choline PET/CT were calculated by standardized maximum uptake value (SUVmax) at 4 hours and SUVmax at 1 hour as reference, respectively. Furthermore, univariate logistic regression analysis was carried out to identify independent predictive factors of positivity with 64Cu-PSMA-617 PET/CT.

RESULTS

An overall positivity with 64Cu-PSMA-617 PET/CT was found in 32 patients (74.4%) versus 19 (44.2%) with 18F-choline PET/CT. Specifically, after stratifying for prostate-specific antigen (PSA) values, we found a good performance of 64Cu-PSMA-617 PET/CT at low PSA levels compared to 18F-choline PET/CT, with a DR of 57.1% versus 14.3% for PSA 0.2-0.5 ng/mL (P = .031), and of 60% versus 30% with PSA 0.5-1 ng/mL. At univariate binary logistic regression analysis, PSA level was the only independent predictor of 64Cu-PSMA-617 PET/CT positivity. No significant difference in terms of DR for both 64Cu-PSMA-617 PET/CT and 18F-choline PET/CT was found according to different Gleason score subgroups.

CONCLUSION

In our study cohort, a better performance was observed for 64Cu-PSMA-617 PET/CT compared to 18F-choline PET/CT in restaging after BCR, especially in patients with low PSA values.

Для цитирования: Cantiello Francesco, Crocerossa Fabio, Russo Giorgio Ivan, Gangemi Vincenzo, Ferro Matteo, Vartolomei Mihai Dorin, Lucarelli Giuseppe, Mirabelli Maria, Scafuro Chiara, Ucciero Giuseppe, De Cobelli Ottavio, Morgia Giuseppe, Damiano Rocco, Cascini Giuseppe Lucio. Comparison Between 64Cu-PSMA-617 PET/CT and 18F-Choline PET/CT Imaging in Early Diagnosis of Prostate Cancer Biochemical Recurrence.. Clinical genitourinary cancer. 2018. DOI: 10.1016/j.clgc.2018.05.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.