Traffic injury prevention · 2015

Biofidelity assessment of the 6-year-old ATDs in lateral impact.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Yaek J L, Li Y, Lemanski P J, Begeman P C, Rouhana S W, Cavanaugh J M

Аннотация

OBJECTIVES: The objective of this study was to assess and compare the current lateral impact biofidelity of the shoulder, thorax, abdomen, and pelvis of the Q6, Q6s, and Hybrid III (HIII) 6-year-old anthropomorphic test devices (ATDs) through lateral impact testing.

METHODS: A series of lateral impact pendulum tests, vertical drop tests, and Wayne State University (WSU) sled tests was performed, based on the procedures detailed in ISO/TR 9790 (1999) and scaling to the 6-year-old using Irwin et al. ( 2002 ). The HIII used in this study was tested with the Ford-designed abdomen described in Rouhana ( 2006 ) and Elhagediab et al. ( 2006 ). The data collected from the 3 different ATDs were filtered using SAE J211 (SAE International 2003 ), aligned using the methodology described by Donnelly and Moorhouse ( 2012 ), and compared for each body region tested (shoulder, thorax, abdomen, and pelvis). The biofidelity performance in lateral impact for the 3 ATDs was assessed against the scaled biofidelity targets published in Irwin et al. ( 2002 ), the abdominal biofidelity target suggested in van Ratingen et al. ( 1997 ), and the biofidelity targets published in Rhule et al. ( 2013 ). Regional and overall biofidelity rankings for each of the 3 ATDs were performed using both the ISO 9790 biofidelity rating system (ISO/TR 9790 1999) and the NHTSA's external biofidelity ranking system (BRS; Rhule et al. 2013 ).

RESULTS: All 3 6-year-old ATD's pelvises were rated as least biofidelic of the 4 body regions tested, based on both the ISO and BRS biofidelity rating systems, followed by the shoulder and abdomen, respectively. The thorax of all 3 ATDs was rated as the most biofidelic body region using the aforementioned biofidelity rating systems. The HIII 6-year-old ATD was rated last in overall biofidelity of the 3 tested ATDs, based on both rating systems. The Q6s ATD was rated as having the best overall biofidelity using both rating systems.

CONCLUSIONS: All 3 ATDs are more biofidelic in the thorax and abdomen than the shoulder and pelvis, with the pelvis being the least biofidelic of all 4 tested body regions. None of the 3 tested 6-year-old ATDs had an overall ranking of 2.0 or less, based on the BRS ranking. Therefore, it is expected that none of the 3 ATDs would mechanically respond like a postmortem human subject (PMHS) in a lateral impact crash test based on this ranking system. With respect to the ISO biofidelity rating, the HIII dummy would be considered unsuitable and the Q-series dummies would be considered marginal for assessing side impact occupant protection.