MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/opx.0000000000000180

Медицинская библиотека · Optometry and vision science : official publication of the American Academy of Optometry · 2014

Two-step technique for posterior optic buttonholing of intraocular lens.

Agarwal Tushar, Jhanji Vishal, Singh Digvijay, Khokhar Sudarshan

СтатьяПеревод в очереди

Аннотация

PURPOSE: This study aims to describe a two-step surgical technique for placement of a posterior chamber intraocular lens (IOL) in cases with crystalline lens subluxation resulting from non-progressive zonular dialysis.

METHODS

The first stage entails a phacoemulsification with creation of a 4-mm posterior capsular opening using an automated vitrector. The second stage performed 6 weeks later includes an anterior vitrectomy and injection of a foldable three-piece IOL in the sulcus. The haptics of IOL are positioned in the sulcus while the optic is pushed behind the posterior capsular opening therefore "buttonholing" the IOL.

RESULTS

Seven eyes of seven patients with posttraumatic zonular dialysis were operated using this technique. Follow-up of all cases revealed a well-centered IOL with good postoperative visual acuity (20/20 to 20/80).

CONCLUSIONS

Our two-stage surgical technique precludes the insertion of capsular tension ring in cases with non-progressive zonular dialysis. The technique is recommended in the presence of less than or equal to 6 clock hours of zonular dialysis with preexisting posterior capsular tear or herniation of vitreous in the anterior chamber.

Для цитирования: Agarwal Tushar, Jhanji Vishal, Singh Digvijay, Khokhar Sudarshan. Two-step technique for posterior optic buttonholing of intraocular lens.. Optometry and vision science : official publication of the American Academy of Optometry. 2014. DOI: 10.1097/opx.0000000000000180.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.