m+Medelevator.RU
← Поиск публикаций
American journal of physiology. Heart and circulatory physiology · 2014

Ultrasound imaging with bolus delivered contrast agent for the detection of angiogenesis and blood flow irregularities.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Korpisalo Petra, Hytönen Jarkko P, Laitinen Johannes T T, Närväinen Johanna, Rissanen Tuomas T, Gröhn Olli H, Ylä-Herttuala Seppo

Аннотация

Highly increased blood flow and vascularity after angiogenic gene therapy have raised concerns of shunting and hemangioma-like blood pool formation that might decrease effective perfusion and ruin the beneficial effects of the therapy. Contrast enhanced ultrasound is a promising noninvasive tool for studying skeletal muscle perfusion. The objectives of the present study were to test bolus and infusion administrations of ultrasound microbubble contrast media in imaging vascular growth in skeletal muscle and assess the functionality of vessels grown with angiogenic gene therapy. Contrast enhanced ultrasound was used to study changes in skeletal muscle perfusion in normal and gene-transduced rabbit hindlimbs 6 days after gene transfer. Adenoviral gene transfer of VEGF (10e(9)-10e(11) viral particles) or β-galactosidase control gene (10e(11) viral particles) was done under anesthesia and induced up to 16-fold increases in relative tissue perfusion. Contrast intensity versus time curves were plotted and analyzed for contrast kinetics. Bolus administration of the contrast media was highly feasible in analyzing skeletal muscle blood flow and its kinetics. Maximal signal intensity of the bolus signal reflected relative changes in both blood flow and volume equally to the infusion method. Flow irregularities were detected after angiogenic gene therapy. In conclusion, bolus delivery of ultrasound contrast agent is highly feasible for the relative analysis of both quantity and quality of blood flow after angiogenic gene therapy. The kinetics of blood flow can and should be studied more extensively in both preclinical and clinical trials of angiogenic gene therapy since there is increasing evidence of flow irregularities in angiogenic vessels.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты