OBJECTIVE

To investigate the role of hemocoagulase to prevent pulmonary hemorrhage in critical newborns on mechanical ventilation.

DESIGN

Randomized controlled trial.

SETTING

Neonatal Intensive Care Unit of an affiliated hospital of a Medical University.

CHILDREN: Seventy-two critical newborn infants on mechanical ventilation.

INTERVENTION: The involved neonates were divided randomly into two groups. Forty-one patients were treated with prophylactic hemocoagulase(dripped through the endotracheal tube), and other 31 neonates served as controls.

OUTCOME MEASURES: Incidence of pulmonary hemorrhage, time of ceasing pulmonary hemorrhage if occurred, time of withdrawing of mechanical ventilation in the survivors, and mortality.

RESULTS

The incidence of pulmonary hemorrhage (12% vs 42%) and the time of ceasing pulmonary hemorrhage (1.36 +/- 0.65 vs 3.58 +/- 0.82, days), were significantly less in infants treated with prophylactic hemocoagulase as compared with the controls (P<0.05). The time to withdrawal of mechanical ventilation was less in the intervention group (3.20 +/- 0.45 vs 5.04 +/- 1.51 days) (P < 0.05). The mortality in children who received hemocoagulase was 22.0%, which was significantly less than controls (41.9 %) (P < 0.05).

CONCLUSION

Prophylactic use of hemocoagulase in mechanically ventilated neonates is effective against pulmonary hemorrhage.

Для цитирования: Shi Yuan, Zhao Jinning, Tang Shifang, Pan Feng, Liu Lei, Tian Zhaoxia, Li Huangqiang. Effect of hemocoagulase for prevention of pulmonary hemorrhage in critical newborns on mechanical ventilation: a randomized controlled trial.. Indian pediatrics. 2008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.