m+Medelevator.RU
← Поиск публикаций
Clinical and experimental dental research · 2025

Impact of Autoclaving on the Dimensional Stability of 3D-Printed Guides for Orthodontic Mini-Implant Insertion - An In Vitro Study.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

David Samuel, Hüfner Mira, Rauch Nicole, Kerberger Robert, Drescher Dieter, Brunello Giulia, Becker Kathrin

Аннотация

OBJECTIVES: This study aimed to assess the effect of the printing process itself and steam autoclaving on the geometrical stability of 3D-printed guides for mini-implant insertion.

MATERIAL AND METHODS: Fifty guides (n = 10 per group) were printed with five printer/resin combinations (PRCs) from the same STL file using either digital light processing (DLP/EG, DLP/Next, DLP/Opti), desktop stereolithography (SLA/DSG) or liquid crystal display stereolithography printers (LCD/Amber). Half were sterilized by steam autoclaving with Cycle 1 (121°C, 1 bar, 20.5 min), half with Cycle 2 (134°C, 2 bars, 5.5 min). Before (T0) and after sterilization (T1) the guides were scanned with a structured light 3D scanner, and selected guides also with micro-CT for validation. Linear measurements were performed in three axes on STL, and on T0 and T1 scans. Linear mixed-effects models were used, followed by post-hoc tests in case of significance.

RESULTS: Measurements at T0 and T1 differed significantly from STL in both x- and y-axis (4 and 3 PRCs, respectively) (p < 0.05); in z-axis only DLP/Next showed significant differences between T0 and STL (p < 0.001). The comparison between T0 and T1 revealed significant differences in x-axis for DLP/Next and DLP/Opti after Cycle 1 and Cycle 2, respectively (p < 0.05), while in the y-axis no intra-group difference was recorded. In the z-axis all PRCs except for SLA/DSG exhibited significant shrinkage (for Cycles 1 or 2). Differences between the two cycles at T1 were registered only in z-axis (DLP/Next and LCD/Amber).

CONCLUSIONS: Compared with the original, all PRCs except for SLA/DSG presented significant changes in their dimensional stability owing to the printing process itself and/or the sterilization. If these changes are of clinical significance, they remain to be verified.

CLINICAL RELEVANCE: With the utilized design, the guides fabricated with SLA provided lower dimensional changes as compared to the ones produced by the other printing techniques.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты