Reusing surgical materials for cataract surgery: an assessment of potential contamination.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Shukla Aakriti Garg, Chang David F, Dhanaseelan Thamizhselvi, Vivekanandan Vellam Ramakrishnan, Gubert Joseph, Robin Alan L, Venkatesh Rengaraj

Аннотация

PURPOSE: To evaluate microbiological cultures of cataract surgical devices and products that were reused for multiple cases.

SETTING: Aravind Eye Hospital, Pondicherry, Tamil Nadu, India.

DESIGN: Prospective cohort study.

METHODS: Samples from multiple surgical instruments and products that were reused for consecutive cataract surgeries underwent bacterial and fungal cultures and were monitored alongside positive controls for 7 days. This included instruments that were processed using immediate use steam sterilization (IUSS) between cases (eg, surgical cannulas, syringes, phacoemulsification and coaxial/bimanual irrigation/aspiration [I/A] tips, phacoemulsification and I/A sleeves) (Group 1), instruments that were used without sterilization between cases (eg, phacoemulsification tubing/handpieces, coaxial I/A handpieces) (Group 2), and the residual (unused) fluid from balanced salt solution bags after being used for multiple patients (Group 3).

RESULTS: 3333 discrete samples were collected from all 3 product groups that were reused across multiple patients. In all collected samples, no bacterial or fungal growth was observed. Of the 3241 cataract surgeries that used reused and IUSS-sterilized instruments alongside instrument sets cultured on the same day and balanced salt solution bags shared across multiple patients, no eyes developed endophthalmitis over a 6-week follow-up period.

CONCLUSIONS: Bacterial or fungal growth was not found in extensive microbiological cultures of IUSS-sterilized ophthalmic surgical instruments and cataract surgical products that were reused in multiple patients. This microbiological data complements clinical endophthalmitis data from 2 million consecutive cases at the Aravind Eye Hospital, suggesting that their instrument and surgical supply processing practices may allow for safe and sustainable ophthalmic care.