Impact of an ultraviolet air sterilizer on cardiac surgery patients, a randomized clinical trial.
СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Heredia-Rodríguez María, Álvarez-Fuente Elisa, Bustamante-Munguira Juan, Poves-Alvarez Rodrigo, Fierro Inmaculada, Gómez-Sánchez Esther, Gómez-Pesquera Estefanía, Lorenzo-López Mario, Eiros José María, Álvarez Francisco Javier, Tamayo Eduardo
Аннотация
BACKGROUND: Numerous studies have evaluated the use of ultraviolet-C devices for terminal disinfection in hospitals, however, to date there is little information about the device's final impact on patients. We investigated the effect of an ultraviolet air sterilizer (UVAS) on the clinical outcomes of cardiac surgery patients.
MATERIALS AND METHODS: This random, prospective and non-interventional study included 1097 adult patients undergoing elective cardiac surgery: 522 stayed in an ICU room with UVAS (Medixair®) and 575 patients ICU room without UVAS and were used as a control. The primary outcome measure was to evaluate the effect of a UVAS on the overall prevalence of nosocomial infections in postoperative cardiac patients in ICUs.
RESULTS: No significant differences in ventilator-associated pneumonia (4.6% vs. 5.0%, p=0.77) and total infection (14.0% vs. 15.5%, p=0.45) rates were detected in patients with and without the UVAS. The length of stay in the intensive care unit and at the hospital was similar in both groups, UVAS (4.6 (8.2) days and 18.3 (5.5) days) and without UVAS (4.6 (7.3) days and 19.2 (18.6) days). The 30-day in-hospital mortality rate was 5.3%, no significant differences between groups were observed (p=0.053).
CONCLUSION: Novel ultraviolet-C technology has not been shown to significantly reduce nosocomial infections or mortality rates in cardiac surgery patients.
MATERIALS AND METHODS: This random, prospective and non-interventional study included 1097 adult patients undergoing elective cardiac surgery: 522 stayed in an ICU room with UVAS (Medixair®) and 575 patients ICU room without UVAS and were used as a control. The primary outcome measure was to evaluate the effect of a UVAS on the overall prevalence of nosocomial infections in postoperative cardiac patients in ICUs.
RESULTS: No significant differences in ventilator-associated pneumonia (4.6% vs. 5.0%, p=0.77) and total infection (14.0% vs. 15.5%, p=0.45) rates were detected in patients with and without the UVAS. The length of stay in the intensive care unit and at the hospital was similar in both groups, UVAS (4.6 (8.2) days and 18.3 (5.5) days) and without UVAS (4.6 (7.3) days and 19.2 (18.6) days). The 30-day in-hospital mortality rate was 5.3%, no significant differences between groups were observed (p=0.053).
CONCLUSION: Novel ultraviolet-C technology has not been shown to significantly reduce nosocomial infections or mortality rates in cardiac surgery patients.