m+Medelevator.RU
← Поиск публикаций
Clinical oral investigations · 2023

Impact of effervescent denture cleaning tablets on color and surface characteristics of additively manufactured and hand-cast splint materials.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kalyoncuoğlu Ülkü Tuğba, Atik Ezgi

Аннотация

OBJECTIVES: This study is to evaluate the color stability, surface roughness, and hardness of additively manufactured and hand-cast splint materials after a 6-month commercially available denture cleaning tablet immersion simulation.

MATERIALS AND METHODS: Disc-shaped additively manufactured and hand-cast auto polymerizing acrylic resin specimens were prepared (N = 40 each). All specimens were exposed to coffee solution totally 2 days. Thereafter, all specimens were immersed into three different effervescent solutions that simulated 6 months of clinical use. The total color change (ΔE*ab), surface roughness (Ra), and Vickers hardness (Vh) were measured at baseline and after immersion protocols. A two-way ANOVA and Bonferroni's post hoc test were used for color change. The dependent t-test and ANOVA were used for roughness and hardness evaluation.

RESULTS: Additively manufactured splint materials were more affected by coffee immersion. It was observed that all denture cleaning tablets induced a noticeable alteration in color of the specimens (p < 0.05). Roughness and hardness measurement changes after solution immersions were statistically significant for both splint groups (p < 0.05). On the other hand, distilled water and denture cleaning tablets created similar roughness and hardness measurements at baseline and after immersion.

CONCLUSIONS: After 6 months use of tested cleaning tables, the color stability, surface roughness, and hardness of both groups were affected. The evaluation of the surface properties of splint materials could be recommended to the dentists in periodic controls during splint treatments.

CLINICAL RELEVANCE: The use effervescent denture cleaning tablets altered the surface characteristics of tested splint materials over time with nonsignificant difference between each other. After 6 months, awareness should be raised about surface characteristics of splint materials.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты