MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/trf.13638

Медицинская библиотека · Transfusion · 2016

Antioxidant power as a quality control marker for completeness of amotosalen and ultraviolet A photochemical treatments in platelet concentrates and plasma units.

Abonnenc Mélanie, Crettaz David, Tacchini Philippe, Di Vincenzo Luciana, Sonego Giona, Prudent Michel, Tissot Jean-Daniel, Lion Niels

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Pathogen inactivation treatments such as INTERCEPT aim to make sure blood and blood-derived products are free of pathogens before using them for transfusion purposes. At present, there is no established quality control assay that assesses the completeness of the treatment. As INTERCEPT is a photochemical treatment known to generate reactive oxygen species we sought to use the antioxidant power (AOP) of the blood product as a marker of treatment execution. In this perspective, we evaluated an electrochemically based miniaturized system, the EDEL technology, for measuring the AOP in both platelet concentrates (PCs) and plasma.

STUDY DESIGN AND

METHODS

Aliquots were withdrawn from PCs or plasma units before and after INTERCEPT treatment and a few microliters were directly deposited into the EDEL sensor for the AOP measurement. The result is expressed in EDEL, an arbitrary unit (micromolar equivalent of ascorbic acid).

RESULTS

The INTERCEPT treatment resulted in a significant decrease of the AOP. An AOP threshold of 66.5, 89.0, 59.8, and 131.5 EDEL was determined for apheresis PCs collected from female and male donors, buffy coat PCs, and plasma units, respectively. Below the threshold value, INTERCEPT treatment is considered to be executed. Additionally, we showed that the presence of the photosensitizer in combination with the ultraviolet A illumination is required to observe the AOP decrease.

CONCLUSION

The measurement of the AOP of PCs and plasma units can be used to document the completeness of the INTERCEPT treatment.

Для цитирования: Abonnenc Mélanie, Crettaz David, Tacchini Philippe, Di Vincenzo Luciana, Sonego Giona, Prudent Michel, Tissot Jean-Daniel, Lion Niels. Antioxidant power as a quality control marker for completeness of amotosalen and ultraviolet A photochemical treatments in platelet concentrates and plasma units.. Transfusion. 2016. DOI: 10.1111/trf.13638.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.