MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.chroma.2020.461784

Медицинская библиотека · Journal of chromatography. A · 2020

Improving Quantification of tabun, sarin, soman, cyclosarin, and sulfur mustard by focusing agents: A field portable gas chromatography-mass spectrometry study.

Kelly John T, Qualley Anthony, Hughes Geoffrey T, Rubenstein Mitchell H, Malloy Thomas A, Piatkowski Tedeusz

СтатьяПеревод в очереди

Аннотация

Commercial gas chromatograph-mass spectrometers, one of which being Inficon's HAPSITE® ER, have demonstrated chemical detection and identification of nerve agents (G-series) and blistering agents (mustard gas) in the field; however most analyses relies on self-contained or external calibration that inherently drifts over time. We describe an analytical approach that uses target-based thermal desorption standards, called focusing agents, to accurately calculate concentrations of chemical warfare agents that are analyzed by gas chromatograph-mass spectrometry. Here, we provide relative response factors of focusing agents (2-chloroethyl ethyl sulfide, diisopropyl fluorophosphate, diethyl methylphosphonate, diethyl malonate, methyl salicylate, and dichlorvos) that are used to quantify concentrations of tabun, sarin, soman, cyclosarin and sulfur mustard loaded on thermal desorption tubes (Tenax® TA). Aging effects of focusing agents are evaluated by monitoring deviations in quantification as thermal desorption tubes age in storage at room temperature and relative humidity. The addition of focusing agents improves the quantification of tabun, sarin, soman, cyclosarin and sulfur mustard that is analyzed within the same day as well as a 14-day period. Among the six focusing agents studied here, diisopropyl fluorophosphate has the best performance for nerve agents (G-series) and blistering agents (mustard gas) compared to other focusing agents in this work and is recommended for field use for quantification. The use of focusing agent in the field leads to more accurate and reliable quantification of Tabun (GA), Sarin (GB), Soman (GD), Cyclosarin (GF) and Sulfur Mustard (HD) than the traditional internal standard. Future improvements on the detection of chemical, biological, radiological, nuclear, and explosive materials (CBRNE) can be safely demonstrated with standards calibrated for harmful agents.

Для цитирования: Kelly John T, Qualley Anthony, Hughes Geoffrey T, Rubenstein Mitchell H, Malloy Thomas A, Piatkowski Tedeusz. Improving Quantification of tabun, sarin, soman, cyclosarin, and sulfur mustard by focusing agents: A field portable gas chromatography-mass spectrometry study.. Journal of chromatography. A. 2020. DOI: 10.1016/j.chroma.2020.461784.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.