MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0359572

Медицинская библиотека · PloS one · 2026

Development and pilot implementation of CERMATA: A digital referral-based vision screening platform for Indonesian primary school children.

Darusman Kianti Raisa, Kartika Alicia, Caroline Christella, Wihardji Tanessa Audrey, Pelangi Bunga, Basrowi Ray Wagiu, Moeloek Nila Faried

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Refractive error is a leading treatable cause of visual impairment among school-aged children, yet implementation of standardized school-based vision screening remains inconsistent in many low- and middle-income countries. CERMATA is a web-based digital platform that integrates the validated WHOeyes mobile application with referral management and program monitoring.

METHODS

This cross-sectional pilot implementation study evaluated the operational feasibility and preliminary screening performance of CERMATA in two primary schools participating in the initial implementation phase of the CERMATA program in Jakarta, Indonesia. Seventy-two children aged 9-12 years completed both CERMATA screening and standardized Snellen visual acuity assessment on the same day. Referral-level reduced visual acuity was defined as presenting visual acuity worse than 6/9 in either eye. Screening performance, agreement, and receiver operating characteristic (ROC) analysis were evaluated at the participant level using the poorer eye.

RESULTS

According to the Snellen reference assessment, 58 participants (80.6%) met the referral criterion. CERMATA demonstrated a sensitivity of 96.6%, specificity of 71.4%, positive predictive value of 93.3%, negative predictive value of 83.3%, and overall accuracy of 91.7%. Agreement with the reference assessment was substantial (κ = 0.719), and ROC analysis demonstrated excellent discrimination (AUC = 0.914; 95% CI, 0.83-1.00). All participants included in the screening performance analysis completed both assessments, supporting the operational feasibility of the screening workflow.

CONCLUSION

In this pilot implementation study, CERMATA demonstrated promising screening performance and operational feasibility for identifying reduced vision in older primary school-aged children. Larger multicenter implementation studies are warranted to confirm its performance, scalability, and integration into routine eye-care pathways before national-scale implementation.

Для цитирования: Darusman Kianti Raisa, Kartika Alicia, Caroline Christella, Wihardji Tanessa Audrey, Pelangi Bunga, Basrowi Ray Wagiu, Moeloek Nila Faried. Development and pilot implementation of CERMATA: A digital referral-based vision screening platform for Indonesian primary school children.. PloS one. 2026. DOI: 10.1371/journal.pone.0359572.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.