DOI 10.1007/s44402-026-00145-w
Diagnostic Accuracy of Teacher-Administered School Vision Screening: A Systematic Review and Meta-Analysis.
Аннотация
PURPOSE: To determine the diagnostic performance (sensitivity [SE] and specificity [SP]) of vision screening conducted by teachers compared to a gold-standard visual examination performed by eye care professionals for identifying refractive errors in children.
METHODS
This systematic review and meta-analysis searched PubMed, Web of Science and Scopus for studies involving children aged 4-18 years. Methodological quality was assessed using the QUADAS-2 tool, and diagnostic accuracy was synthesised using a Bivariate Random-Effects Model.
RESULTS
Nineteen articles (24 study arms) were included, involving approximately 5.7 million children and 34,500 teachers. Global meta-analysis revealed a pooled SE of 76.8% (95% CI: 62.4%, 86.9%), SP of 93.6% (95% CI: 85.7%, 97.3%) and area under the curve (AUC) of 0.92. Low-risk studies showed more conservative values (SE: 72.1% [95% CI: 57.2%, 83.4%]; SP: 96.0% [95% CI: 89.3%, 98.5%]) compared to high/unclear risk investigations (SE: 80.1% [95% CI: 55.6%, 92.8%]; SP: 90.8% [95% CI: 71.4%, 97.5%]). Additionally, (1) studies using a 6/12 cutoff showed more consistent diagnostic performance (minimum SE: 72.6%); (2) sensitivity was significantly higher in younger children (89.29%) than in adolescents (45.45%) and (3) studies specifying a cycloplegia protocol reported superior performance, with SE > 92.0% and SP > 72.0%. Overlapping confidence intervals and bias variability suggest that diagnostic accuracy depends on both reference standard rigour and teacher training/motivation.
CONCLUSION
Vision screening by teachers is a viable strategy with high potential. Studies using a 6/12 cutoff demonstrated more consistent diagnostic performance, although this may reflect differences in study quality. The success of the programme depends on solid practical training and rigorous validation protocols. Involving all classroom teachers proves to be the preferred strategy for maximising early detection, while the selected teachers model stands out for its greater logistical feasibility. Continuous teacher training remains essential for the sustainability of vision screening programmes.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.