DOI 10.1097/ijg.0000000000002727
Reading Performance and Eye Movement Patterns in Glaucoma.
Аннотация
PRCIS: Glaucoma patients of similar age and educational level, compared with healthy individuals, exhibit a greater number of saccades and fixations during eye-tracking-aloud reading, resulting in reduced reading speed.
PURPOSE: To evaluate reading performance in patients with glaucoma compared with controls using an eye tracker and to explore the potential confounding effects of patients' contrast sensitivity and cognition.
MATERIALS AND
METHODS
A cross-sectional study was conducted with 111 participants (57 with glaucoma and 54 controls) with a best-corrected visual acuity of ≥0.5 logMAR. Cognition was assessed using the Montreal Cognitive Assessment, and contrast sensitivity was measured with the Freiburg Visual Acuity and Contrast Test. A reading performance evaluation was conducted using the Minnesota Low Vision Reading Test displayed on slides on a computer screen. Reading speed was calculated in words per minute, and an eye tracker was used to analyze saccade and fixation patterns during the reading task.
RESULTS
Mean age was 61.8 (±11.6) and 66.5 (±13.7) in the glaucoma and control groups, respectively ( P =0.05). Best-corrected visual acuity was 0.18 (±0.16) and 0.04 (±0.10) logMAR in the glaucoma and control groups, respectively ( P <0.001). Montreal Cognitive Assessment score was 21.8 (±3.5) in the glaucoma and 21.4 (±4.0) in the control group ( P =0.566). A total of 26% of the glaucoma group and 33% of the control group had at least a primary education. Controls read faster and showed fewer saccades and fixations than patients with glaucoma ( P <0.05) across all 5 slides.
CONCLUSIONS
Patients with glaucoma exhibit poorer reading performance, as evidenced by eye-tracking data, compared with controls of similar age, cognitive function, and educational level.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.