MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00417-010-1578-4

Медицинская библиотека · Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2011

Surface quality of human corneal lenticules after femtosecond laser surgery for myopia comparing different laser parameters.

Kunert Kathleen S, Blum Marcus, Duncker Gernot I W, Sietmann Rabea, Heichel Jens

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

To determine the surface characteristics of human corneal lenticules after femtosecond laser surgery for myopia.

METHODS

The Carl Zeiss Meditec AG VisuMax® femtosecond laser system was used for refractive correction called Femtosecond Lenticule Extraction on 24 myopic eyes. The surface regularity on the refractive corneal lenticules recovered was evaluated by assessing scanning electron microscopy images using an established scoring system. Three different energy levels 150, 180, and 195 nJ were compared (n = 8 in each group).

RESULTS

Surface irregularities were caused by tissue bridges, cavitation bubbles, or scratches. The surface regularity index (R(2) = 0.74) decreased as pulse energy increased. The average surface regularity score obtained was 7.5 for 150 nJ, 7.25 for 180 nJ, and 6.25 for 195 nJ.

CONCLUSIONS

The human corneal lenticules created with the VisuMax® femtosecond laser system are of predictable, good-quality surface. This study shows the influence of pulse energy on surface regularity in human eyes. Further studies should focus on optimization of laser parameters as well as surgical technique to improve the regularity of the corneal stromal bed and so make the advantages of the femtosecond laser technology over conventional techniques clearer in the future.

Для цитирования: Kunert Kathleen S, Blum Marcus, Duncker Gernot I W, Sietmann Rabea, Heichel Jens. Surface quality of human corneal lenticules after femtosecond laser surgery for myopia comparing different laser parameters.. Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie. 2011. DOI: 10.1007/s00417-010-1578-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.