MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/s25154775

Медицинская библиотека · Sensors (Basel, Switzerland) · 2025

Direct Detection of Orthoflavivirus via Gold Nanorod Plasmon Resonance.

Ribeiro Erica Milena de Castro, Dias Bruna de Paula, Ferreira Cyntia Silva, Santos Samara Mayra Soares Alves Dos, Gopalsamy Rajiv Gandhi, Martins Estefânia Mara do Nascimento, Magalhães Cintia Lopes de Brito, Fonseca Flavio Guimarães da, Coelho Luiz Felipe Leomil, Fantini Cristiano, Ladeira Luiz Orlando, Borges Lysandro Pinto, Silva Breno de Mello

СтатьяПеревод в очереди

Аннотация

Dengue, Zika, yellow fever, chikungunya, and Mayaro arboviruses represent an increasing threat to public health because of the serious infections they cause annually in many countries. Serological diagnosis of these viruses is challenging, making the development of new diagnostic strategies imperative. In this study, we investigated the effectiveness of gold nanorods (GNRs) functionalized with specific anti-dengue and anti-orthoflavivirus antibodies in detecting viral particles. GNRs were created with a length-to-width ratio of up to 5.5, a size of 71.4 ± 6.5 nm, and a light absorption peak at 927 nm, and they were treated with 4 mM polyethyleneimine. These GNRs were attached to a small amount of monoclonal antibodies that target flaviviruses, and the viral particles were detected by measuring the localized surface plasmon resonance using an UV-Vis/NIR spectrometer. The tests found Orthoflavivirus dengue and Orthoflavivirus zikaense in diluted human serum and ground-up mosquitoes, with the lowest detectable amount being 100 PFU/mL. The GNRs described in this study can be used to enhance flavivirus diagnostic tests or to develop new, faster, and more accurate diagnostic techniques. Additionally, the functionalized GNRs presented here are promising for supporting virological surveillance studies in mosquitoes. Our findings highlight a fast and highly sensitive method for detecting Orthoflavivirus in both human and mosquito samples, with a detection limit as low as 100 PFU/mL.

Для цитирования: Ribeiro Erica Milena de Castro, Dias Bruna de Paula, Ferreira Cyntia Silva, Santos Samara Mayra Soares Alves Dos, Gopalsamy Rajiv Gandhi, Martins Estefânia Mara do Nascimento, Magalhães Cintia Lopes de Brito, Fonseca Flavio Guimarães da, Coelho Luiz Felipe Leomil, Fantini Cristiano, Ladeira Luiz Orlando, Borges Lysandro Pinto, Silva Breno de Mello. Direct Detection of Orthoflavivirus via Gold Nanorod Plasmon Resonance.. Sensors (Basel, Switzerland). 2025. DOI: 10.3390/s25154775.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.