A standardized nomenclature for spectrogram EEG patterns: Inter-rater agreement and correspondence with common intensive care unit EEG patterns.

Zafar Sahar F, Amorim Edilberto, Williamsom Craig A, Jing Jin, Gilmore Emily J, Haider Hiba A, Swisher Christa, Struck Aaron, Rosenthal Eric S, Ng Marcus, Schmitt Sarah, Lee Jong W, Brandon Westover M

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To determine the inter-rater agreement (IRA) of a standardized nomenclature for EEG spectrogram patterns, and to estimate the probability distribution of ictal-interictal continuum (IIC) patterns vs. other EEG patterns within each category in this nomenclature.

METHODS

We defined seven spectrogram categories: "Solid Flames", "Irregular Flames", "Broadband-monotonous", "Narrowband-monotonous", "Stripes", "Low power", and "Artifact". Ten electroencephalographers scored 115 spectrograms and the corresponding raw EEG samples. Gwet's agreement coefficient was used to calculate IRA.

RESULTS

Solid Flames represented seizures or IIC patterns 69.4% of the time. Irregular Flames represented seizures or IIC patterns 38.7% of the time. Broadband-monotonous primarily corresponded with seizures or IIC (54.3%) and Narrowband-monotonous with focal or generalized slowing (43.8%). Stripes were associated with burst-suppression (37.2%) and generalized suppression (34.4%). Low Power category was associated with generalized suppression (94%). There was "near perfect" agreement for Solid Flames (κ = 94.36), Low power (κ = 92.61), and Artifact (κ = 93.72). There was "substantial agreement" for all other categories (κ = 74.65-79.49).

CONCLUSIONS

This EEG spectrogram nomenclature has high IRA among electroencephalographers.

SIGNIFICANCE: The nomenclature can be a useful tool for EEG screening. Future studies are needed to determine if using this nomenclature shortens time to IIC identification, and how best to use it in practice to reduce time to intervention.

Для цитирования: Zafar Sahar F, Amorim Edilberto, Williamsom Craig A, Jing Jin, Gilmore Emily J, Haider Hiba A, Swisher Christa, Struck Aaron, Rosenthal Eric S, Ng Marcus, Schmitt Sarah, Lee Jong W, Brandon Westover M. A standardized nomenclature for spectrogram EEG patterns: Inter-rater agreement and correspondence with common intensive care unit EEG patterns.. Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology. 2020. DOI: 10.1016/j.clinph.2020.05.032.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.