MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3129/i08-150

Медицинская библиотека · Canadian journal of ophthalmology. Journal canadien d'ophtalmologie · 2008

Effect of bimatoprost on intraocular pressure after cataract surgery.

Unal Mustafa, Yücel Iclal

Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

An increase in intraocular pressure (IOP) frequently occurs after otherwise uneventful phacoemulsification cataract surgery. This study was conducted to determine the efficacy of bimatoprost 0.03% drops given preoperatively in preventing IOP rise following phacoemulsification cataract surgery.

METHODS

In this prospective, randomized, double-masked, placebo-controlled study, 91 eyes of 85 patients scheduled to have clear corneal phacoemulsification cataract surgery were randomly divided into 2 groups. One hour before surgery, 1 group (48 eyes) received 1 drop of bimatoprost 0.03%, and the other group (43 eyes) received 1 drop of a balanced saline solution (placebo). A masked observer measured IOP preoperatively, and 3 and 24 hours postoperatively. Anterior chamber cellular reaction was measured on the first day after surgery. Preoperative and postoperative central corneal thickness (CCT) was assessed.

RESULTS

The mean IOP changes from baseline were not statistically different between the 2 groups at 3 hours (p = 0.618). At 24 hours, there was a statistically significant difference between the mean IOP changes of the groups (p = 0.001). The incidence of IOP elevation greater than 5 or 10 mm Hg at 24 hours was significantly higher in the control group (9 of 43 eyes) than the bimatoprost group (3 of 48 eyes) (p = 0.039). Anterior chamber reaction was not increased by bimatoprost. Mean CCT change was not different between the groups at 24 hours (p = 0.615).

INTERPRETATION: When compared with placebo, prophylactic use of 1 drop of bimatoprost before phacoemulsification cataract surgery failed to produce a significantly different effect on IOP levels from placebo at 3 hours postoperatively, but it caused a significant IOP reduction at 24 hours.

Для цитирования: Unal Mustafa, Yücel Iclal. Effect of bimatoprost on intraocular pressure after cataract surgery.. Canadian journal of ophthalmology. Journal canadien d'ophtalmologie. 2008. DOI: 10.3129/i08-150.