DOI 10.1161/circinterventions.123.013579
Prognostic Impact of Left Atrial Appendage Patency After Device Closure.
Аннотация
BACKGROUND
The prognostic impact of left atrial appendage (LAA) patency, including those with and without visible peri-device leak (PDL), post-LAA closure in patients with atrial fibrillation, remains elusive.
METHODS
Patients with atrial fibrillation implanted with the WATCHMAN 2.5 device were prospectively enrolled. The device surveillance by cardiac computed tomography angiography was performed at 3 months post-procedure. Adverse events, including stroke/transient ischemic attack (TIA), major bleeding, cardiovascular death, all-cause death, and the combined major adverse events (MAEs), were compared between patients with complete closure and LAA patency.
RESULTS
Among 519 patients with cardiac computed tomography angiography surveillance at 3 months post-LAA closure, 271 (52.2%) showed complete closure, and LAA patency was detected in 248 (47.8%) patients, including 196 (37.8%) with visible PDL and 52 (10.0%) without visible PDL. During a median of 1193 (787-1543) days follow-up, the presence of LAA patency was associated with increased risks of stroke/TIA (adjusted hazard ratio for baseline differences, 3.22 [95% CI, 1.17-8.83]; P=0.023) and MAEs (adjusted hazard ratio, 1.12 [95% CI, 1.06-1.17]; P=0.003). Specifically, LAA patency with visible PDL was associated with increased risks of stroke/TIA (hazard ratio, 3.66 [95% CI, 1.29-10.42]; P=0.015) and MAEs (hazard ratio, 3.71 [95% CI, 1.71-8.07]; P=0.001), although LAA patency without visible PDL showed higher risks of MAEs (hazard ratio, 3.59 [95% CI, 1.28-10.09]; P=0.015). Incidences of stroke/TIA (2.8% versus 3.0% versus 6.7% versus 22.2%; P=0.010), cardiovascular death (0.9% versus 0% versus 1.7% versus 11.1%; P=0.005), and MAEs (4.6% versus 9.0% versus 11.7% versus 22.2%; P=0.017) increased with larger PDL (0, >0 to ≤3, >3 to ≤5, or >5 mm). Older age and discontinuing antiplatelet therapy at 6 months were independent predictors of stroke/TIA and MAEs in patients with LAA patency.
CONCLUSIONS
LAA patency detected by cardiac computed tomography angiography at 3 months post-LAA closure is associated with unfavorable prognosis in patients with atrial fibrillation implanted with WATCHMAN 2.5 device.
REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03788941.