Vascular Closure Devices For Axillary Artery Access: A Systematic Review and Meta-Analysis.

Koziarz Alex, Kennedy Sean A, Awad El-Karim Ghassan, Tan Kong T, Oreopoulos George D, Kalra Sanjog, Etz Christian D, Rajan Dheeraj K, Mafeld Sebastian

Систематический обзорСтатьяМетаанализПеревод в очереди

Аннотация

PURPOSE: To evaluate the technical success and complication rates of vascular closure devices (VCDs) in the axillary artery.

MATERIALS AND

METHODS

MEDLINE and Embase were searched independently by two reviewers to identify observational studies from inception through October 2021. The following outcomes were meta-analyzed: technical success, hematoma, dissection, pseudoaneurysm, infection, and local neurological complications. Complications were also graded as mild, moderate, and severe. A logistic regression evaluating the influence of sheath size for the outcome of technical success rate was performed using individual patient-level data.

RESULTS

Of 1496 unique records, 20 observational studies were included, totaling 915 unique arterial access sites. Pooled estimates were as follows: technical success 84.8% (95% confidence interval [CI]: 78%-89.7%, I2=60.4%), hematoma 7.9% (95% CI: 5.8%-10.6%, I2=0%), dissection 3.1% (95% CI: 1.3%-7.3%, I2=0%), pseudoaneurysm 2.7% (95% CI: 1.3%-5.7%, I2=0%), infection <1% (95% CI: 0%-5.7%, I2=20.5%), and local neurological complications 2.7% (95% CI: 1.7%-4.4%, I2=0%). There was a significant negative association between sheath size and technical success rate (odds ratio [OR]: 0.87 per 1 French (Fr) increase in sheath size, 95% CI: 0.80-0.94, p=0.0005). Larger sheath sizes were associated with a greater number of access-site complications (adjusted odds ratio [aOR]: 1.21 per 1 Fr increase sheath size, 95% CI: 1.04-1.40, p=0.013).

CONCLUSIONS

Off-label use of VCDs in the axillary artery provides an 85% successful closure rate and variable complication rate, depending on the primary procedure and sheath size. Larger sheaths were associated with a lower technical success and greater rate of access-related complications.

CLINICAL IMPACT: Safe arterial access is the foundation for arterial intervention. While the common femoral artery is a well established access site, alternative arterial access sites capable of larger sheath sizes are needed in the modern endovascular era. This article provides the largest synthesis to date on the use of vascular closure devices for percutaneous axillary artery access in endovascular intervention. It should serve clinicians with added confidence around this approach in terms of providing a reference for technical success and complications. Clinically, this data is relevant for patient consent purposes as well as for practice quality improvement in setting safety standards for this access site.

Для цитирования: Koziarz Alex, Kennedy Sean A, Awad El-Karim Ghassan, Tan Kong T, Oreopoulos George D, Kalra Sanjog, Etz Christian D, Rajan Dheeraj K, Mafeld Sebastian. Vascular Closure Devices For Axillary Artery Access: A Systematic Review and Meta-Analysis.. Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists. 2023. DOI: 10.1177/15266028221147451.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.