MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2021.05.006

Медицинская библиотека · Heart rhythm · 2021

Gain in real-world cardiac resynchronization therapy efficacy with SyncAV dynamic optimization: Heart failure hospitalizations and costs.

Varma Niraj, Hu Yajing, Connolly Allison T, Thibault Bernard, Singh Balbir, Mont Lluis, Nabutovsky Yelena, Zareba Wojciech

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

SyncAV, a device-based cardiac resynchronization therapy (CRT) algorithm, promotes electrical optimization by dynamically adjusting atrioventricular intervals.

OBJECTIVE

The purpose of this study was to evaluate the impact of SyncAV on heart failure hospitalizations (HFHs) and related costs in a real-world CRT cohort.

METHODS

Patients with SyncAV-capable CRT devices followed by remote monitoring and enrolled in Medicare fee-for-service for at least 1 year preimplant and up to 2 years postimplant were studied. Patients with SyncAV OFF were 4:1 matched to those with SyncAV ON on preimplant HFH rate, demographics, comorbidities, disease etiology, and left bundle branch block. HFHs were determined from the primary diagnosis of inpatient hospitalizations, and the cost for each event was the sum of Medicare, supplemental insurance, and patient payment.

RESULTS

After 4:1 propensity score matching, 3630 patients were studied (mean age 75 ± 8 years; 1386 [38%] female), including 726 (25%) patients with SyncAV ON. The pre-CRT HFH rate was 0.338 HFH events per patient-year. Overall, CRT diminished the HFH rate to 0.204 events per patient-year (P < .001). SyncAV elicited a larger reduction in HFH rate (SyncAV ON: hazard ratio [HR] 0.52; 95% confidence interval [CI] 0.41-0.66; P < .001 and SyncAV OFF: HR 0.68; 95% CI 0.59-0.77; P < .001). After 2 years, the HFH rate was lower in the SyncAV ON group than in the SyncAV OFF group (0.143 HFHs per patient-year vs 0.193 HFHs per patient-year; HR 0.70; 95% CI 0.55-0.89; P = .003) and fewer HFHs were followed by 30-day HFH readmissions (4.41% vs 7.68%; P = .003) and 30-day all-cause hospital readmissions (7.04% vs 10.01%; P = .010). The total 2-year HFH-associated costs per patient were lower with SyncAV ON (difference $1135; 90% CI $93-$2109; P = .038).

CONCLUSION

This large, real-world, propensity score-matched study demonstrates that SyncAV CRT is associated with significantly reduced HFHs and associated costs, incremental to standard CRT.

Для цитирования: Varma Niraj, Hu Yajing, Connolly Allison T, Thibault Bernard, Singh Balbir, Mont Lluis, Nabutovsky Yelena, Zareba Wojciech. Gain in real-world cardiac resynchronization therapy efficacy with SyncAV dynamic optimization: Heart failure hospitalizations and costs.. Heart rhythm. 2021. DOI: 10.1016/j.hrthm.2021.05.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.