m+Medelevator.RU
← Поиск публикаций
Saudi journal of kidney diseases and transplantation : an official publication of the Saudi Center for Organ Transplantation, Saudi Arabia · 2018

Improvement in dialysis-related adverse events with use of body composition monitoring.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Raza Syed Hammad, Hashmi Muhammad Nauman, Elairon Philip, Riolo Adam Henoch, Hejaili Fayez, Al-Sayyari Abdulla A

Аннотация

This study aims to utilize body composition monitor (BCM) device to achieve euvolemic status in problematic dialysis patients and to evaluate its clinical outcome. One hundred and five hemodialysis (HD) patients were enrolled based on difficulty in achieving dry weight. The reasons for enrollment in the study were (a) recurrent intradialytic hypotension, (b) intradialytic hypertension, (c) intradialytic muscle cramps, or (d) the presence of comorbid conditions that make clinical assessment of dry weight difficult (e.g., cirrhosis of liver, heart failure, severe malnutrition, or morbid obesity). Following initial assessment of hydration status using BCM device, dry weight for each patient was adjusted accordingly (upward, downward, or unchanged). The patients were, thereafter, monitored over a 15-week period for possible resultant change in the clinical and hemodynamic parameters. Forty-two patients were monitored due to hypertension, 18 due to hypotension, 10 due to hypotension and cramps, and 35 due to comorbid conditions that make clinical assessment of dry weight difficult. At the conclusion of study period, there was improvement in the monitored parameters. Hypertension improved in 79% of the patient with hypertension, hypotension in 90%, and hypotension with cramps in 90%. In the comorbid group, BCM monitoring provided better insight to clinical problem management in 80% cases. Overall quality of BCM assessments was 96.1%. In the hypertension group, mean blood pressure decreased by 10.9 mm Hg in the whole group (P = 0.0006), the drop was 3 mm Hg in the patients dialyzing with HD (P = 0.0006) and 8.6 mm Hg in those on hemodiafiltration (HDF) (P = 0.08). In the comorbid conditions group, the mean blood pressure rose by 22.5 mm Hg in the whole group (P 0.00001), 21.5 mm Hg in the patients dialyzing with HD (P = 0.00001) and 21.5 mm Hg in those on HDF (P = 0.0004). BCM monitoring together with clinical assessment is a useful tool which when appropriately applied reduces the incidence of dialysis-related complications.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты