m+Medelevator.RU
← Поиск публикаций
Journal of the American College of Cardiology · 2006

Cost-effectiveness of a microvolt T-wave alternans screening strategy for implantable cardioverter-defibrillator placement in the MADIT-II-eligible population.

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Chan Paul S, Stein Kenneth, Chow Theodore, Fendrick Mark, Bigger J Thomas, Vijan Sandeep

Аннотация

OBJECTIVES: This study was designed to compare the cost-effectiveness of implantable cardioverter-defibrillator (ICD) placement with and without risk stratification with microvolt T-wave alternans (MTWA) testing in the MADIT-II (Second Multicenter Automatic Defibrillator Implantation Trial) eligible population.

BACKGROUND: Implantable cardioverter-defibrillators have been shown to prevent mortality in the MADIT-II population. Microvolt T-wave alternans testing has been shown to be effective in risk stratifying MADIT-II-eligible patients.

METHODS: On the basis of published data, cost-effectiveness of three therapeutic strategies in MADIT-II-eligible patients was assessed using a Markov model: 1) ICD placement in all; 2) ICD placement in patients testing MTWA non-negative;, and 3) medical management. Outcomes of expected cost, quality-adjusted life-years (QALYs), and incremental cost-effectiveness were determined for patient lifetime.

RESULTS: Under base-case assumptions, providing ICDs only to those who test MTWA non-negative produced a gain of 1.14 QALYs at an incremental cost of 55,700 dollars when compared to medical therapy, resulting in an incremental cost-effectiveness ratio (ICER) of 48,700 dollars/QALY. When compared with a MTWA risk-stratification strategy, placing ICDs in all patients resulted in an ICER of 88,700 dollars/QALY. Most (83%) of the potential benefit was achieved by implanting ICDs in the 67% of patients who tested MTWA non-negative. Results were most sensitive to the effectiveness of MTWA as a risk-stratification tool, MTWA negative screen rate, cost and efficacy of ICD therapy, and patient risk for arrhythmic death.

CONCLUSIONS: Risk stratification with MTWA testing in MADIT-II-eligible patients improves the cost-effectiveness of ICDs. Implanting defibrillators in all MADIT-II-eligible patients, however, is not cost-effective, with one-third of patients deriving little additional benefit at great expense.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты