Use of Continuous Glucose Monitoring in Pump Therapy Sensor Augmented Pump or Automated Insulin Delivery in Different Age Groups (0.5 to <26 Years) With Type 1 Diabetes From 2018 to 2021: Analysis of the German/Austrian/Swiss/Luxemburg Diabetes Prospective Follow-up Database Registry.

van den Boom Louisa, Auzanneau Marie, Woelfle Joachim, Sindichakis Marina, Herbst Antje, Meraner Dagmar, Hake Kathrin, Klinkert Christof, Gohlke Bettina, Holl Reinhard W

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

AIM: Insulin pump, continuous glucose monitoring (CGM), and sensor augmented pump (SAP) technology have evolved continuously leading to the development of automated insulin delivery (AID) systems. Evaluation of the use of diabetes technologies in people with T1D from January 2018 to December 2021.

METHODS

A patient registry (Diabetes Prospective Follow-up Database [DPV]) was analyzed for use of SAP (insulin pump + CGM ≥90 days, no automated dose adjustment) and AID (HCL or LGS/PLGS). In total 46,043 people with T1D aged 0.5 to <26 years treated in 416 diabetes centers (Germany, Austria, Luxemburg, and Switzerland) were included and stratified into 4 groups A-D according to age. Additionally, TiR and HbA1c were analyzed.

RESULTS

From 2018 to 2021, there was a significant increase from 28.7% to 32.9% (sensor augmented pump [SAP]) and 3.5% to 16.6% (AID) across all age groups, with the most frequent use in group A (<7 years, 38.8%-40.2% and 10.3%-28.5%). A similar increase in SAP and AID use was observed in groups B (7 to <11 years) and C (11 to <16 years): B: +15.8 PP, C: +15.9 PP. HbA1c improved significantly in groups C and D (16 to <26 years) (both P < .01). Time in range (TiR) increased in all groups (A: +3 PP; B: +5 PP; C: +5 PP; D: +5 PP; P < 0.01 for each group). Insulin pumps (61.0% versus 53.4% male) and SAP (33.5% versus 28.9% male) are used more frequently in females.

CONCLUSION

In recent years, we found an increasing use of new diabetes technologies and an improvement in metabolic control (TiR) across all age groups.

Для цитирования: van den Boom Louisa, Auzanneau Marie, Woelfle Joachim, Sindichakis Marina, Herbst Antje, Meraner Dagmar, Hake Kathrin, Klinkert Christof, Gohlke Bettina, Holl Reinhard W. Use of Continuous Glucose Monitoring in Pump Therapy Sensor Augmented Pump or Automated Insulin Delivery in Different Age Groups (0.5 to <26 Years) With Type 1 Diabetes From 2018 to 2021: Analysis of the German/Austrian/Swiss/Luxemburg Diabetes Prospective Follow-up Database Registry.. Journal of diabetes science and technology. 2023. DOI: 10.1177/19322968231156601.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.