Pediatric diabetes · 2018
Long-term study of tubeless insulin pump therapy compared to multiple daily injections in youth with type 1 diabetes: Data from the German/Austrian DPV registry.
Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Danne Thomas, Schwandt Anke, Biester Torben, Heidtmann Bettina, Rami-Merhar Birgit, Haberland Holger, Müther Silvia, Khodaverdi Semik, Haak Thomas, Holl Reinhard W, DPV Initiative
Аннотация
OBJECTIVE: To examine glycemic control in youth with type 1 diabetes (T1D) who switched from multiple daily injections (MDI) to a tubeless insulin pump (Omnipod Insulin Management System, Insulet Corporation, Billerica, Massachusetts) compared to patients who continued MDI therapy over a 3-year time period.
RESEARCH DESIGN AND METHODS: This retrospective analysis of the German/Austrian Diabetes Patienten Verlaufsdokumentation registry included data from 263 centers and 2529 patients <20 years (n = 660 tubeless insulin pump; n = 1869 MDI) who initiated treatment on a tubeless insulin pump as of January 1, 2013 and had 1 year of data preswitch from MDI and 3 years of data postswitch to a tubeless pump. Outcomes included the change in glycated hemoglobin (HbA1c), insulin dose, and body mass index (BMI) SD score (SDS).
RESULTS: Youth with T1D who switched from MDI therapy to a tubeless insulin pump showed better glycemic control at 1 year compared to patients who continued MDI treatment, adjusted mean ± SE: 7.5% ± 0.03% (58 mmol/mol) vs 7.7% ± 0.02% (61 mmol/mol); P < .001, with no between-group difference at 2 and 3 years. Total daily insulin dose was lower (P < .001) in the tubeless insulin pump group, 0.80 ± 0.01, 0.81 ± 0.01, and 0.85 ± 0.01 U/kg, vs the MDI group, 0.89 ± 0.01, 0.94 ± 0.01, and 0.97 ± 0.01 U/kg, at 1, 2, and 3 years, respectively (all P < .001). BMI SDS increased in both groups and was not different over time.
CONCLUSIONS: Treatment with a tubeless insulin pump in youth with T1D was associated with improvements in glycemic control compared to MDI after 1 year and appears to be an effective alternative to MDI.
RESEARCH DESIGN AND METHODS: This retrospective analysis of the German/Austrian Diabetes Patienten Verlaufsdokumentation registry included data from 263 centers and 2529 patients <20 years (n = 660 tubeless insulin pump; n = 1869 MDI) who initiated treatment on a tubeless insulin pump as of January 1, 2013 and had 1 year of data preswitch from MDI and 3 years of data postswitch to a tubeless pump. Outcomes included the change in glycated hemoglobin (HbA1c), insulin dose, and body mass index (BMI) SD score (SDS).
RESULTS: Youth with T1D who switched from MDI therapy to a tubeless insulin pump showed better glycemic control at 1 year compared to patients who continued MDI treatment, adjusted mean ± SE: 7.5% ± 0.03% (58 mmol/mol) vs 7.7% ± 0.02% (61 mmol/mol); P < .001, with no between-group difference at 2 and 3 years. Total daily insulin dose was lower (P < .001) in the tubeless insulin pump group, 0.80 ± 0.01, 0.81 ± 0.01, and 0.85 ± 0.01 U/kg, vs the MDI group, 0.89 ± 0.01, 0.94 ± 0.01, and 0.97 ± 0.01 U/kg, at 1, 2, and 3 years, respectively (all P < .001). BMI SDS increased in both groups and was not different over time.
CONCLUSIONS: Treatment with a tubeless insulin pump in youth with T1D was associated with improvements in glycemic control compared to MDI after 1 year and appears to be an effective alternative to MDI.