MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/14670100.2018.1460025

Медицинская библиотека · Cochlear implants international · 2018

Cochlear helix and duct length identification - Evaluation of different curve fitting techniques.

Schurzig Daniel, Timm Max Eike, Lexow G Jakob, Majdani Omid, Lenarz Thomas, Rau Thomas S

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

Within the field of cochlear implantation (CIs), the role of utilizing patient-specific cochlear anatomy for choosing the optimal implant electrode is becoming increasingly important. Unfortunately, performing detailed anatomical measurements of a cochlea using clinical imaging data is rather time consuming and hence difficult to implement into the clinical routine. In order to accelerate clinical cochlear anatomy evaluations, previously developed mathematical models can be adjusted to the patient-specific anatomy by measuring just a few overall cochlear dimensions. However, the accuracy of model-based cochlear anatomy estimations is unclear, and incorrect evaluations may lead to false conclusions regarding the suitability of specific implant electrodes.

METHODS

Based on 10 cochleae, an error evaluation of various commonly used curve fitting approaches for cochlear shape and duct length approximation was conducted. Spline tracings of the cochlear contours were used as reference values for the various approximations.

RESULTS

Parameterized average cochlear helix models and two of five analytical approaches were found to be suitable for reconstructing the cochlear helical shape and estimating its length.

DISCUSSION: Spline curve reconstructions are the most accurate and reliable method for assessing patient-specific cochlear geometry, especially in the case of anatomical irregularities. The most accurate results within the group of model-based evaluations still resulted in mean overall cochlear length deviations of approximately 5%.

CONCLUSION

Spline curve reconstructions appear to be the best option for anatomical diagnostics in clinical practice. Retrospective studies can be performed to further evaluate model-based evaluations.

Для цитирования: Schurzig Daniel, Timm Max Eike, Lexow G Jakob, Majdani Omid, Lenarz Thomas, Rau Thomas S. Cochlear helix and duct length identification - Evaluation of different curve fitting techniques.. Cochlear implants international. 2018. DOI: 10.1080/14670100.2018.1460025.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.