DOI 10.1097/pec.0000000000001034

Медицинская библиотека · Pediatric emergency care · 2019

The Use of Ultrasound-Measured Optic Nerve Sheath Diameter to Predict Ventriculoperitoneal Shunt Failure in Children.

Lin Sophia D, Kahne Kimberly R, El Sherif Amira, Mennitt Kevin, Kessler David, Ward Mary J, Platt Shari L

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The goal of this study was to assess the accuracy of ultrasound-measured optic nerve sheath diameter (ONSD) as a screen for ventriculoperitoneal shunt failure.

METHODS

We prospectively enrolled a convenience sample of children presenting to the ED with suspected shunt failure. The ONSD was measured by ultrasound and compared with computed tomography/magnetic resonance imaging (CT/MRI) and neurosurgical impression. We defined shunt failure on ultrasound as an ONSD greater than 4.0 mm in infants 12 months and younger or greater than 4.5 mm in children older than 12 months. A single emergency radiologist at our institution read all CTs and MRIs for categorical determination of shunt failure. We defined shunt failure based on neurosurgical impression as a decision to admit and perform shunt revision. We report test characteristics and 95% confidence intervals of ONSD as a predictor for shunt failure.

RESULTS

We enrolled 32 subjects. The sensitivities of ONSD compared with CT/MRI and neurosurgical impression, 60.0% and 75.0%, respectively, were low. However, the negative predictive values of ONSD compared with CT/MRI and neurosurgical impression were 90.0% and 95.0%, respectively.

CONCLUSIONS

Optic nerve sonography may be a useful tool to identify children presenting with suspected ventriculoperitoneal shunt failure who do not require further imaging. This would reduce the use of CT scan and exposure to ionizing radiation in children with suspected shunt malfunction who do not require neurosurgical intervention. Consideration of additional risk factors and a larger sample size may yield stronger results.

Для цитирования: Lin Sophia D, Kahne Kimberly R, El Sherif Amira, Mennitt Kevin, Kessler David, Ward Mary J, Platt Shari L. The Use of Ultrasound-Measured Optic Nerve Sheath Diameter to Predict Ventriculoperitoneal Shunt Failure in Children.. Pediatric emergency care. 2019. DOI: 10.1097/pec.0000000000001034.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.