DOI 10.1111/tmi.13594

Медицинская библиотека · Tropical medicine & international health : TM & IH · 2021

Rational use of ultrasonography with triaging of patients to detect dengue plasma leakage in resource limited settings: a prospective cohort study.

Sigera Ponsuge Chathurani, Weeratunga Praveen, Deepika Fernando Sumadhya, Lakshitha De Silva Nipun, Rodrigo Chaturaka, Rajapakse Senaka

СтатьяНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

To compare the traditional haematocrit-based criteria (>20% rise above baseline) with ultrasonography for diagnosing plasma leakage in dengue fever and to identify clinical indicators for triaging patients in resource-limited settings when the demand for ultrasonography is high.

METHODS

The Colombo Dengue Study is a prospective observational cohort study recruiting dengue patients in the first three days of dengue fever, before plasma leakage. Serial haematocrit assessments and ultrasonography were performed in patients recruited from October 2017 to February 2020. Clinical signs/symptoms and laboratory investigation results independently associated with ultrasound detected plasma leakage were identified with a derivation cohort and confirmed in a validation cohort.

RESULTS

129 of 426 patients had ultrasonography-confirmed plasma leakage while 146 had a haematocrit rise >20%. Those positive on ultrasonography were also likely to fulfil the haematocrit-based criteria (OR: 4.42, 95% CI: 2.85-6.86), but the two groups did not overlap fully. In the derivation cohort (n = 317), platelet count <97 000/µl, AST/ALT > 51 IU/l and having abdominal pain in the first three days of fever were independent predictors of ultrasound-detected plasma leakage. In the validation cohort (n = 109), the combination of low platelet count and high aminotransferase level had better predictive capacity in terms of sensitivity and specificity.

CONCLUSION

Dengue patients should be monitored with both serial haematocrit and ultrasonography whenever possible and plasma leakage should be diagnosed by either one of these criteria. If accessibility to scans is limited, platelet count, serum transaminase levels and presence of abdominal pain are useful to triage patients.

Для цитирования: Sigera Ponsuge Chathurani, Weeratunga Praveen, Deepika Fernando Sumadhya, Lakshitha De Silva Nipun, Rodrigo Chaturaka, Rajapakse Senaka. Rational use of ultrasonography with triaging of patients to detect dengue plasma leakage in resource limited settings: a prospective cohort study.. Tropical medicine & international health : TM & IH. 2021. DOI: 10.1111/tmi.13594.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.