In silicodosimetry for a prostate cancer treatment using198Au nanoparticles.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Angelocci Lucas Verdi, Sgrignoli Sabrina Spigaroli, de Souza Carla Daruich, Antunes Paula Cristina Guimarães, Rostelato Maria Elisa Chuery Martins, Zeituni Carlos Alberto

Аннотация

Objective. To estimate dose rates delivered by using radioactive198Au nanoparticles for prostate cancer nanobrachytherapy, identifying contribution by photons and electrons emmited from the source.Approach. Utilizingin silicomodels, two different anatomical representations were compared: a mathematical model and a unstructured mesh model based on the International Commission on Radiological Protection (ICRP) Publication 145 phantom. Dose rates by activity were calculated to the tumor and nearby healthy tissues, including healthy prostate tissue, urinary bladder wall and rectum, using Monte Carlo code MCNP6.2.Main results. Results indicate that both models provide dose rate estimates within the same order of magnitude, with the mathematical model overestimating doses to the prostate and bladder by approximately 20% compared to the unstructured mesh model. The discrepancies for the tumor and rectum were below 4%. Photons emmited from the source were defined as the primary contributors to dose to other organs, while 97.9% of the dose to the tumor was due to electrons emmited from the source.Significance. Our findings emphasize the importance of model selection in dosimetry, particularly the advantages of using realistic anatomical phantoms for accurate dose calculations. The study demonstrates the feasibility and effectiveness of198Au nanoparticles in achieving high dose concentrations in tumor regions while minimizing exposure to surrounding healthy tissues. Beta emissions were found to be predominantly responsible for tumor dose delivery, reinforcing the potential of198Au nanoparticles in localized radiation therapy. We advocate for using realistic body phantoms in further research to enhance reliability in dosimetry for nanobrachytherapy, as the field still lacks dedicated protocols.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты