MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0200354

Медицинская библиотека · PloS one · 2018

Feasibility and effects of intra-dialytic low-frequency electrical muscle stimulation and cycle training: A pilot randomized controlled trial.

McGregor Gordon, Ennis Stuart, Powell Richard, Hamborg Thomas, Raymond Neil T, Owen William, Aldridge Nicolas, Evans Gail, Goodby Josie, Hewins Sue, Banerjee Prithwish, Krishnan Nithya S, Ting Stephen M S, Zehnder Daniel

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVES

Exercise capacity is reduced in chronic kidney failure (CKF). Intra-dialytic cycling is beneficial, but comorbidity and fatigue can prevent this type of training. Low-frequency electrical muscle stimulation (LF-EMS) of the quadriceps and hamstrings elicits a cardiovascular training stimulus and may be a suitable alternative. The main objectives of this trial were to assess the feasibility and efficacy of intra-dialytic LF-EMS vs. cycling.

DESIGN, SETTING, PARTICIPANTS, AND MEASUREMENTS: Assessor blind, parallel group, randomized controlled pilot study with sixty-four stable patients on maintenance hemodialysis. Participants were randomized to 10 weeks of 1) intra-dialytic cycling, 2) intra-dialytic LF-EMS, or 3) non-exercise control. Exercise was performed for up to one hour three times per week. Cycling workload was set at 40-60% oxygen uptake (VO2) reserve, and LF-EMS at maximum tolerable intensity. The control group did not complete any intra-dialytic exercise. Feasibility of intra-dialytic LF-EMS and cycling was the primary outcome, assessed by monitoring recruitment, retention and tolerability. At baseline and 10 weeks, secondary outcomes including cardio-respiratory reserve, muscle strength, and cardio-arterial structure and function were assessed.

RESULTS

Fifty-one (of 64 randomized) participants completed the study (LF-EMS = 17 [77%], cycling = 16 [80%], control = 18 [82%]). Intra-dialytic LF-EMS and cycling were feasible and well tolerated (9% and 5% intolerance respectively, P = 0.9). At 10-weeks, cardio-respiratory reserve (VO2 peak) (Difference vs. control: LF-EMS +2.0 [95% CI, 0.3 to 3.7] ml.kg-1.min-1, P = 0.02, and cycling +3.0 [95% CI, 1.2 to 4.7] ml.kg-1.min-1, P = 0.001) and leg strength (Difference vs. control: LF-EMS, +94 [95% CI, 35.6 to 152.3] N, P = 0.002 and cycling, +65.1 [95% CI, 6.4 to 123.8] N, P = 0.002) were improved. Arterial structure and function were unaffected.

CONCLUSIONS

Ten weeks of intra-dialytic LF-EMS or cycling improved cardio-respiratory reserve and muscular strength. For patients who are unable or unwilling to cycle during dialysis, LF-EMS is a feasible alternative.

Для цитирования: McGregor Gordon, Ennis Stuart, Powell Richard, Hamborg Thomas, Raymond Neil T, Owen William, Aldridge Nicolas, Evans Gail, Goodby Josie, Hewins Sue, Banerjee Prithwish, Krishnan Nithya S, Ting Stephen M S, Zehnder Daniel. Feasibility and effects of intra-dialytic low-frequency electrical muscle stimulation and cycle training: A pilot randomized controlled trial.. PloS one. 2018. DOI: 10.1371/journal.pone.0200354.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.