Frequency resolution and hearing loss.
Аннотация
Future scientific and diagnostic interest in frequency resolution requires an evaluation of the different methods that are available to measure it. We compared three methods: (1) pure-tone thresholds in broadband noise, (2) pure-tone thresholds in the presence of a fixed pure-tone masker and (3) psychoacoustical tuning curves. We additionally obtained estimates of temporal integration and of speech intelligibility in noise. Three subject groups were tested: 10 normals, 13 subjects with a noise-induced hearing loss and 18 subjects with a cochlear hearing loss but no history of noise exposure. Generally the three measures of frequency resolution show moderate agreement with each other. Poor frequency resolution is invariably associated with a pure-tone threshold loss. Temporal integration appears unrelated either to the pure-tone threshold loss or frequency resolution. Some of the measures of frequency resolution display significant correlation with speech intelligibility in noise. However, since both variables are correlated with pure-tone threshold loss the exact relationship between frequency resolution and speech intelligibility cannot be clearly established.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.