m+Medelevator.RU
← Поиск публикаций
Quality of life research : an international journal of quality of life aspects of treatment, care and rehabilitation · 2024

The Hemodialysis Distress Thermometer for Caregivers (HD-DT-C): development and testing of the psychometric properties of a new tool for screening psychological distress among family caregivers of adults on hemodialysis.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sousa Helena, Ribeiro Oscar, Figueiredo Daniela

Аннотация

PURPOSE: To develop and test the measurement properties of the HD-DT-C, a new tool designed to facilitate the screening of psychological distress and its sources in family caregivers of adults on hemodialysis.

METHODS: The present investigation was carried out in three phases: Phase 1 focused on the process of developing and exploring the content validity and clinical utility of the HD-DT-C using a mixed-methods approach and feedback panels; Phase 2, where the psychometric properties of this new tool were tested in a cross-sectional study (n = 106 caregivers); and Phase 3, where the European Portuguese version of the HD-DT-C was translated and culturally adapted into American English using a forward-backward translation procedure, followed by an expert panel review.

RESULTS: Findings suggested that the HD-DT-C was perceived by feedback panels as practical, appropriate, and useful for increasing dialysis provider/family caregiver communication in nephrology centers. The European Portuguese version of the HD-DT-C showed good test-retest reliability (ICC = 0.991 for the barometer and κ ≥ 0.80 in 77% of the checklist items), high diagnostic accuracy (AUC = 0.956), and strong convergent validity (all r ≥ 0.50) with reference measures that assess quality of life, caregiver burden, and symptoms of anxiety and depression. Cutoff scores with good clinical utility (CUI +  ≥ 0.70) were recommended for screening distress in research (≥ 6) and clinical practice (≥ 5).

CONCLUSION: The HD-DT-C is a brief, reliable, valid, and acceptable measure for identifying self-reported psychological distress and its sources among people caring for a family member or friend on hemodialysis. Future research is needed to explore the measurement properties of the American English version of this new tool.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты