Аннотация

PURPOSE: To compare the primary stability of dental implants placed in fibula, iliac crest, and scapula of human cadavers.

MATERIALS AND

METHODS

Straumann Dental Implants (Institut Straumann, Basel, Switzerland) 4.1 mmx10 mm in diameter were placed into bilateral fibula, iliac crest, and scapula of 4 fresh human cadavers. For the assessment of primary stability of implants, installation torque values (ITV) and removal torque values (RTV) were measured using a custom-made strain-gauged torque wrench, and resonance frequency analysis was carried out to quantify the implant stability quotients (ISQ). Bone specimens from each donor site were harvested to perform radiographic and histomorphometric analyses. Linear distance and optical density (OD) measurements were made on digitized parallel periapical radiographs and bone area fraction (BAF) was calculated on digitized images of decalcified histologic sections.

RESULTS

Fibula donor site presented higher ITVs and RTVs and cortical bone height for implants than other sites (P<.05). BAF measurements for iliac crest were higher than fibula and scapula bone donor sites. OD was higher in the iliac crest followed by scapula and fibula.

CONCLUSION

The primary mechanical stability of implants placed in the fibula is higher than those placed in the iliac crest and the scapula, although the bone mass and density around implants in latter sites are higher.

Для цитирования: Akkocaoglu Murat, Cehreli Murat Cavit, Tekdemir Ibrahim, Comert Ayhan, Güzel Elif, Dağdeviren Attila, Akca Kivanc. Primary stability of simultaneously placed dental implants in extraoral donor graft sites: a human cadaver study.. Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons. 2007. DOI: 10.1016/j.joms.2005.12.073.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.