MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.transproceed.2010.02.065

Медицинская библиотека · Transplantation proceedings · 2010

Decreased fresh gas flow cannot compensate for an increased operating room temperature in maintaining body temperature during donor hepatectomy for living liver donor hepatectomy.

Cheng K-W, Wang C-H, Chen C-L, Jawan B, Wang C-C, Concejero A M, Wang S-H, Liu Y-W, Yong C-C, Yang C-H, Huang C-J

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The purpose of this study was to compare the effect of various combinations of fresh gas flow (FGF) of anesthesia and different ambient operation room temperatures (ORT) on changes in nasopharyngeal temperature (NT) among living donors undergoing partial hepatectomy.

METHODS

The anesthesia records of 167 patients were reviewed retrospectively. The patients were allocated into 4 groups: GI (n=37): isoflurane in 2 L FGF and at typical ambient ORT (19 degrees C-21 degrees C); GII (n=11) isoflurane in 1 L FGF and 1 L air at typical ORT; GIII (n=31) isoflurane in 0.5 L FGF at typical ORT; and GIV (n=88) isoflurane in 0.5 L FGF at ORT of 24 degrees C. The changes in NT were compared using a two-way repeated measure analysis of variance (ANOVA) followed by Bonferroni post hoc tests.

RESULTS

Changes of NTs of GIV were significantly higher compared with the other 3 groups, whereas the changes of NTs were the same among GI, GII, and GIII.

CONCLUSION

FGF of different volumes seemed to have no significant effect on intraoperative changes of NT in regular ORT. Low-flow anesthesia combined with ORT of 24 degrees C provided significantly higher NTs at all measured points compared with GI, GII, and GIII.

Для цитирования: Cheng K-W, Wang C-H, Chen C-L, Jawan B, Wang C-C, Concejero A M, Wang S-H, Liu Y-W, Yong C-C, Yang C-H, Huang C-J. Decreased fresh gas flow cannot compensate for an increased operating room temperature in maintaining body temperature during donor hepatectomy for living liver donor hepatectomy.. Transplantation proceedings. 2010. DOI: 10.1016/j.transproceed.2010.02.065.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.