OBJECTIVES

To estimate the potential for solid organ donation; to identify modifiable reasons for nondonation.

DESIGN

Retrospective medical records review.

SETTING

Sixty-nine acute care hospitals in four geographic areas of the United States in 1990, and a stratified random sample of 89 hospitals in three of the same areas and 33 of the same hospitals in 1993.

PATIENTS: PATIENTS < or = 70 yrs of age who were brain dead and medically suitable for donation.

INTERVENTIONS: None.

MEASUREMENTS AND MAIN

RESULTS

Standard forms were used to record patient demographic and hospital information. Reasons for nondonation were coded as "not identified," "family not asked," "consent denied," or "other." The main outcome measures were rate of donation and rates of nonidentification, not asking, and nonconsent. Organ donation occurred among 33% (299/916) of medically suitable cases identified in 1990 (95% confidence interval 30% to 36%). Ninety-four potential donors were not identified, 156 were not asked, 326 families denied consent, and 41 potential donors were categorized as "other," including patients who had suffered a cardiac arrest, and medical examiner prohibition of donation. In the 1993 study, organ donation occurred in an estimated 33% of suitable cases. In 1990, rates of donation were highest among patients <50 yrs of age, patients who died of traumatic causes, and non-Hispanic white patients. Logistic regression showed lower odds of donation for African American patients (odds ratio 0.38, 95% confidence interval 0.23 to 0.63) independent of potentially confounding hospital and patient variables (p=.0001). Donation rates did not vary by hospital size or type.

CONCLUSIONS

Despite legal and policy initiatives, only one third of potential donors became donors in 1990, with similar results in 1993. Extrapolating the 1990 findings to the United States suggests a pool of 13,700 medically suitable donors per year. Prospective identification and requesting donation in all suitable potential donor cases could lead to 1,800 additional donors per year.

Для цитирования: Gortmaker S L, Beasley C L, Brigham L E, Franz H G, Garrison R N, Lucas B A, Patterson R H, Sobol A M, Grenvik N A, Evanisko M J. Organ donor potential and performance: size and nature of the organ donor shortfall.. Critical care medicine. 1996. DOI: 10.1097/00003246-199603000-00012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.