The Journal of pediatrics · 2025

Accuracy of Home Blood Pressure Monitoring in Youth: A Systematic Review and Meta-Analysis.

СтатьяСистематический обзорМетаанализПоддержка исследования: вне правительства СШАПоддержка NIH: внешняя программаНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Cueto Victoria, Medvecky Hugh, Funaro Melissa C, Nugent James T

Аннотация

OBJECTIVE: To evaluate the accuracy of home blood pressure monitoring (HBPM) in youth compared with the reference standard of ambulatory BP monitoring (ABPM).

STUDY DESIGN: MEDLINE, Embase, Web of Science, and Cochrane Library were systematically searched from inception to November 13, 2024. Two authors identified studies testing the accuracy of HBPM compared with ABPM in youth ≤18 years. We assessed outcomes on the continuous scale (mean difference [MD]) or categorical scale (sensitivity, specificity, κ). We conducted a meta-analysis using hierarchical random effects weights.

RESULTS: Of the 2966 titles screened, 26 studies were included (total n = 1992 patients, median 59 per study). Daytime home BP was lower than awake ambulatory BP (systolic MD, -6.4 mmHg [95% CI, -10.7 to -2.0]; diastolic MD, -3.3 mmHg [95% CI, -6.0 to -0.7]). Diagnosing daytime ambulatory hypertension by HBPM had modest sensitivity (0.52-0.64) and good specificity (0.82-0.97), with moderate agreement (κ 0.50-0.65). Accuracy was higher for white coat hypertension (sensitivity, 0.77-0.89; specificity, 0.85-0.94; κ, 0.66-0.73) and specificity was slightly higher for masked hypertension (sensitivity, 0.23-0.38; specificity, 0.92-0.96; κ, 0.27-0.36). Nocturnal home BP was higher than asleep ambulatory BP (systolic MD, 2.6-5.0 mmHg; diastolic MD, 2.2-3.2 mmHg) with moderate agreement (κ, 0.33-0.49). Limitations included different hypertension thresholds and HBPM protocols.

CONCLUSIONS: The accuracy of HBPM may not be sufficient to replace ABPM as a single test. However, HBPM may be a practical alternative when ABPM is not available, particularly when clinic and home BPs are concordant. Future work is needed to determine the best approach to HBPM in clinical practice.