MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/s24165435

Медицинская библиотека · Sensors (Basel, Switzerland) · 2024

Validity and Test-Retest Reliability of Spatiotemporal Running Parameter Measurement Using Embedded Inertial Measurement Unit Insoles.

Riglet Louis, Orliac Baptiste, Delphin Corentin, Leonard Audrey, Eby Nicolas, Ornetti Paul, Laroche Davy, Gueugnon Mathieu

СтатьяПеревод в очереди

Аннотация

Running is the basis of many sports and has highly beneficial effects on health. To increase the understanding of running, DSPro® insoles were developed to collect running parameters during tasks. However, no validation has been carried out for running gait analysis. The aims of this study were to assess the test-retest reliability and criterion validity of running gait parameters from DSPro® insoles compared to a motion-capture system. Equipped with DSPro® insoles, a running gait analysis was performed on 30 healthy participants during overground and treadmill running using a motion-capture system. Using an intraclass correlation coefficient (ICC), the criterion validity and test-retest reliability of spatiotemporal parameters were calculated. The test-retest reliability shows moderate to excellent ICC values (ICC > 0.50) except for propulsion time during overground running at a fast speed with the motion-capture system. The criterion validity highlights a validation of running parameters regardless of speeds (ICC > 0.70). This present study validates the good criterion validity and test-retest reliability of DSPro® insoles for measuring spatiotemporal running gait parameters. Without the constraints of a 3D motion-capture system, such insoles seem to be helpful and relevant for improving the care management of active patients or following running performance in sports contexts.

Для цитирования: Riglet Louis, Orliac Baptiste, Delphin Corentin, Leonard Audrey, Eby Nicolas, Ornetti Paul, Laroche Davy, Gueugnon Mathieu. Validity and Test-Retest Reliability of Spatiotemporal Running Parameter Measurement Using Embedded Inertial Measurement Unit Insoles.. Sensors (Basel, Switzerland). 2024. DOI: 10.3390/s24165435.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.