m+Medelevator.RU
← Поиск публикаций
Journal of physical activity & health · 2024

Assessing the Accuracy of Activity Classification Using Thigh-Worn Accelerometry: A Validation Study of ActiPASS in School-Aged Children.

СтатьяВалидационное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lendt Claas, Hettiarachchi Pasan, Johansson Peter J, Duncan Scott, Lund Rasmussen Charlotte, Narayanan Anantha, Stewart Tom

Аннотация

BACKGROUND: The ActiPASS software was developed from the open-source Acti4 activity classification algorithm for thigh-worn accelerometry. However, the original algorithm has not been validated in children or compared with a child-specific set of algorithm thresholds. This study aims to evaluate the accuracy of ActiPASS in classifying activity types in children using 2 published sets of Acti4 thresholds.

METHODS: Laboratory and free-living data from 2 previous studies were used. The laboratory condition included 41 school-aged children (11.0 [4.8] y; 46.5% male), and the free-living condition included 15 children (10.0 [2.6] y; 66.6% male). Participants wore a single accelerometer on the dominant thigh, and annotated video recordings were used as a reference. Postures and activity types were classified with ActiPASS using the original adult thresholds and a child-specific set of thresholds.

RESULTS: Using the original adult thresholds, the mean balanced accuracy (95% CI) for the laboratory condition ranged from 0.62 (0.56-0.67) for lying to 0.97 (0.94-0.99) for running. For the free-living condition, accuracy ranged from 0.61 (0.48-0.75) for lying to 0.96 (0.92-0.99) for cycling. Mean balanced accuracy for overall sedentary behavior (sitting and lying) was ≥0.97 (0.95-0.99) across all thresholds and conditions. No meaningful differences were found between the 2 sets of thresholds, except for superior balanced accuracy of the adult thresholds for walking under laboratory conditions.

CONCLUSIONS: The results indicate that ActiPASS can accurately classify different basic types of physical activity and sedentary behavior in children using thigh-worn accelerometer data.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты