MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/annhyg/mep095

Медицинская библиотека · The Annals of occupational hygiene · 2009

Workplace determinants of endotoxin exposure in dental healthcare facilities in South Africa.

Singh Tanusha S, Bello Braimoh, Mabe Onnicah D, Renton Kevin, Jeebhay Mohamed F

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

Aerosols generated during dental procedures have been reported to contain endotoxin as a result of bacterial contamination of dental unit water lines. This study investigated the determinants of airborne endotoxin exposure in dental healthcare settings.

METHODS

The study population included dental personnel (n = 454) from five academic dental institutions in South Africa. Personal air samples (n = 413) in various dental jobs and water samples (n = 403) from dental handpieces and basin taps were collected. The chromogenic-1000 limulus amebocyte lysate assay was used to determine endotoxin levels. Exposure metrics were developed on the basis of individually measured exposures and average levels within each job category. Analysis of variance and multivariate linear regression models were constructed to ascertain the determinants of exposure in the dental group.

RESULTS

There was a 2-fold variation in personal airborne endotoxin from the least exposed (administration) to the most exposed (laboratory) jobs (geometric mean levels: 2.38 versus 5.63 EU m(-3)). Three percent of personal samples were above DECOS recommended exposure limit (50 EU m(-3)). In the univariate linear models, the age of the dental units explained the most variability observed in the personal air samples (R(2) = 0.20, P < 0.001), followed by the season of the year (R(2) = 0.11, P < 0.001). Other variables such as institution and total number of dental units per institution also explained a modest degree of variability. A multivariate model explaining the greatest variability (adjusted R(2) = 0.40, P < 0.001) included: the age of institution buildings, total number of dental units per institution, ambient temperature, ambient air velocity, endotoxin levels in water, job category (staff versus students), dental unit model type and age of dental unit.

CONCLUSIONS

Apart from job type, dental unit characteristics are important predictors of airborne endotoxin levels in this setting.

Для цитирования: Singh Tanusha S, Bello Braimoh, Mabe Onnicah D, Renton Kevin, Jeebhay Mohamed F. Workplace determinants of endotoxin exposure in dental healthcare facilities in South Africa.. The Annals of occupational hygiene. 2009. DOI: 10.1093/annhyg/mep095.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.