MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.asjsur.2019.03.005

Медицинская библиотека · Asian journal of surgery · 2019

Sentinel lymph node detection using fluorescein and blue light-emitting diodes in patients with breast carcinoma: A single-center prospective study.

Chang Young Woo, Lee Hye Yoon, Lee Chang Min, Jung Seung Pil, Kim Woo Young, Woo Sang Uk, Lee Jae Bok, Son Gil Soo

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Sentinel lymph node (SLN) biopsy is an essential procedure for lymph node staging in patients with breast carcinoma. Technetium-99m-labelled nanocolloid (99mTc) is the most accurate and widely used lymphatic mapping agent; however, there are concerns pertaining to the associated exposure to radiation. Studies focusing on new agents are required. We aimed to evaluate the feasibility and safety of SLN detection using fluorescein and blue light-emitting diodes (LEDs) in breast carcinoma patients.

METHODS

In this prospective study, a total of 61 patients with breast carcinoma, requiring SLN biopsy, were enrolled. Both fluorescein and 99mTc were intradermally injected into the areola of the affected breast of each patient. SLNs stained with fluorescein were detected using blue LED light first, and then, any remaining SLNs were detected using a gamma detection probe. The detection rate was analyzed, and the presence of complications was investigated.

RESULTS

SLNs dyed with fluorescein using blue LED light were visualized in 57 of 61 patients (93.4%). None of the patients experienced complications related to the use of fluorescein or blue LED light.

CONCLUSIONS

The detection of SLNs using fluorescein and blue LED light was feasible and safe in patients with breast carcinoma. This technique involves the use of visible light, allowing for SLNs to be viewed with the naked eye, and is quantifiable, easy to use, and economical.

Для цитирования: Chang Young Woo, Lee Hye Yoon, Lee Chang Min, Jung Seung Pil, Kim Woo Young, Woo Sang Uk, Lee Jae Bok, Son Gil Soo. Sentinel lymph node detection using fluorescein and blue light-emitting diodes in patients with breast carcinoma: A single-center prospective study.. Asian journal of surgery. 2019. DOI: 10.1016/j.asjsur.2019.03.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.