MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.juro.2011.12.013

Медицинская библиотека · The Journal of urology · 2012

Prospective measurement of patient exposure to radiation during pediatric ureteroscopy.

Kokorowski Paul J, Chow Jeanne S, Strauss Keith, Pennison Melanie, Routh Jonathan C, Nelson Caleb P

СтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

PURPOSE: Few data have been reported regarding radiation exposure during pediatric endourological procedures, including ureteroscopy. We measured radiation exposure during pediatric ureteroscopy and identify opportunities for exposure reduction.

MATERIALS AND

METHODS

We prospectively observed ureteroscopy procedures as part of a quality improvement initiative. Preoperative patient characteristics, operative factors, fluoroscopy settings and radiation exposure were recorded. Our outcomes were entrance skin dose and midline dose (both mGy). Specific modifiable factors were identified as targets for potential quality improvement.

RESULTS

Direct observation was performed in 54 consecutive ureteroscopy procedures. Mean±SD patient age was 14.8±3.8 years (range 7.4 to 19.2), with 9 children being younger than 12 years. Mean±SD entrance skin dose was 46.4±48 mGy. Mean±SD midline dose was 6.2±5.0 mGy. The most important major determinant of radiation dose was total fluoroscopy time (mean±SD 2.68±1.8 minutes) followed by dose rate setting, child anteroposterior diameter and source to skin distance (all p<0.01). Analysis of factors affecting exposure levels revealed that use of ureteral access sheaths (p=0.01) and retrograde pyelography (p=0.04) were significantly associated with fluoroscopy time. We also found that dose rate settings were higher than recommended in up to 43% of cases and ideal C-arm positioning could have reduced exposure by 14% (up to 49% in some cases).

CONCLUSIONS

Children receive biologically significant radiation doses during ureteroscopy procedures. Several modifiable factors contribute to dose and could be targeted in efforts to implement dose reduction strategies.

Для цитирования: Kokorowski Paul J, Chow Jeanne S, Strauss Keith, Pennison Melanie, Routh Jonathan C, Nelson Caleb P. Prospective measurement of patient exposure to radiation during pediatric ureteroscopy.. The Journal of urology. 2012. DOI: 10.1016/j.juro.2011.12.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.