LC-MS/MS and EMIT measure the whole blood concentration of cyclosporine A: The two methods yield concordant results within the dynamic range of the latter, but the former shows broader application scenarios.

Zhang Yuan-Yuan, Guo Hong-Li, Wang Jie, Wang Wei-Jun, Li Yue, Chu Chen-Chao, Wu Chun-Ying, Huang Jian, Hu Ya-Hui, Chen Feng

СтатьяПеревод в очереди

Аннотация

Cyclosporine A (CsA) is a widely used immunosuppressive drug with a narrow therapeutic index and large individual differences. Its therapeutic and toxic effects are closely related to blood drug concentrations, requiring routine therapeutic drug monitoring (TDM). The current main methods for TDM of CsA are enzyme multiplied immunoassay technique (EMIT) and liquid chromatography-tandem mass spectrometry (LC-MS/MS). However, few study on the method comparison of the EMIT and LC-MS/MS for the measurement of whole blood CsA concentration in children has been reported. In this study, we developed a simple and sensitive LC-MS/MS assay for the determination of CsA, and 657 cases of CsA concentrations were determined from 197 pediatric patients by a routine EMIT assay and by the validated in-house LC-MS/MS method on the same batch of samples, aimed to address the aforementioned concern. Consistency between the two assays was evaluated using linear regression and Bland-Altman analysis. The linear range of LC-MS/MS was 0.500-2000 ng/mL and that of the EMIT was 40-500 ng/mL, respectively. Overall, the correlation between the two methods was significant (r-value ranging from 0.8842 to 0.9441). Unsatisfactory consistency was observed in the concentrations < 40 ng/mL (r = 0.7325) and 200-500 ng/mL (r = 0.6851). Bland-Altman plot showed a mean bias of -18.0 % (±1.96 SD, -73.8 to 37.8 %) between EMIT and LC-MS/MS. For Passing-Bablok regression between EMIT and LC-MS/MS did not differ significantly (p > 0.05). In conclusion, the two methods were closely correlated, but the CsA concentration by LC-MS/MS assay was slightly higher than that by EMIT method. Switching from the EMIT assay to the LC-MS/MS method was acceptable, and the LC-MS/MS method will receive broader application in clinical settings due to its better analytical capabilities, but the results need to be further verified in different laboratories.

Для цитирования: Zhang Yuan-Yuan, Guo Hong-Li, Wang Jie, Wang Wei-Jun, Li Yue, Chu Chen-Chao, Wu Chun-Ying, Huang Jian, Hu Ya-Hui, Chen Feng. LC-MS/MS and EMIT measure the whole blood concentration of cyclosporine A: The two methods yield concordant results within the dynamic range of the latter, but the former shows broader application scenarios.. Journal of chromatography. B, Analytical technologies in the biomedical and life sciences. 2024. DOI: 10.1016/j.jchromb.2024.124154.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.