MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/23258160-20190503-03

Медицинская библиотека · Ophthalmic surgery, lasers & imaging retina · 2019

Perfluorodecalin Versus Densiron 68 Heavy Silicone Oil in the Management of Inferior Retinal Detachment Recurrence.

Caporossi Tomaso, Tartaro Ruggero, Finocchio Lucia, Barca Francesco, Giansanti Fabrizio, Franco Fabrizio, Rizzo Stanislao

Сравнительное исследованиеСтатьяVideo-Audio MediaПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVE

To assess the efficacy of perfluorodecalin (PFD) or Densiron 68 heavy silicone oil (HSO) in the management of inferior complex retinal detachment recurrence.

PATIENTS AND

METHODS

A retrospective, comparative consecutive case series study. Twenty-four eyes of 24 patients affected by inferior complex retinal detachment recurrence underwent pars plana vitrectomy with PFD or HSO as endotamponade. All patients recruited were affected by complicated inferior retinal detachments and had already undergone at least one vitreoretinal procedure. The primary endpoint was anatomical success with primary and secondary surgery. The secondary endpoints were functional outcome and inflammatory complications.

RESULTS

Out of 24 cases of inferior retinal detachment recurrence, 12 were tamponed with PFD (PFD group) and 12 with HSO (D68 group). Retinal reattachment rate at first surgery was 50% for the D68 group and 66.6% for the PFD group. Final reattachment rate after two or more surgical operations was 91.6% for the PFD group and 83.3% for the D68 group. Best-corrected visual acuity improved in both groups from a mean of 1.00 logMAR (20/200; standard deviation [SD]: 1) to 0.60 logMAR (20/80; SD: 0.3), and from a mean of 1.81 logMAR (20/2000; SD: 1.1) to a mean of 2.00 logMAR (20/2,000; SD:1) for the PFD and D68 groups, respectively.

CONCLUSION

Both the endotamponades used showed good results in solving inferior retinal detachment recurrence with a slightly better rate in the PFD group, but it was not statistically significant (P > .05). [Ophthalmic Surg Lasers Imaging Retina. 2019;50:274-280.].

Для цитирования: Caporossi Tomaso, Tartaro Ruggero, Finocchio Lucia, Barca Francesco, Giansanti Fabrizio, Franco Fabrizio, Rizzo Stanislao. Perfluorodecalin Versus Densiron 68 Heavy Silicone Oil in the Management of Inferior Retinal Detachment Recurrence.. Ophthalmic surgery, lasers & imaging retina. 2019. DOI: 10.3928/23258160-20190503-03.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.