MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1053/jcan.2002.31064

Медицинская библиотека · Journal of cardiothoracic and vascular anesthesia · 2002

Intrathoracic blood volume index measured by thermodilution for preload monitoring after cardiac surgery.

Reuter Daniel A, Felbinger Thomas W, Moerstedt Karl, Weis Florian, Schmidt Christian, Kilger Erich, Goetz Alwin E

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To investigate the accuracy of measurement of intrathoracic blood volume index by single thermodilution (ITBVI*) and its sensitivity to detect changes in preload after cardiac surgery compared with conventional transpulmonary arterial dye dilution ITBVI and with conventional monitoring (central venous pressure [CVP] and left ventricular end-diastolic area index [EDAI] by transesophageal echocardiography).

DESIGN

Prospective clinical study.

SETTING

University hospital.

PARTICIPANTS

Nineteen patients immediately after cardiac surgery.

INTERVENTIONS: Volume loading was administered with 20 mL of oxypoligelatine (Haemaccel [Behringwerke Aktiengesellschaft Corp, Marburg, Germany]) 3.5% times body mass index over 10 minutes.

MEASUREMENTS AND MAIN

RESULTS

Intrathoracic blood volume index was measured by dye dilution (ITBVI) and thermodilution (ITBVI*) immediately before and after volume loading. Measurements of ITBVI and ITBVI* correlated closely (r = 0.94; p < 0.0001). With volume loading, ITBVI and ITBVI* increased significantly from 877 +/- 195 mL/m(2) to 967 +/- 180 mL/m(2) and from 889 +/- 195 mL/m(2) to 954 +/- 185 mL/m(2). Percent changes in ITBVI (deltaITBVI) and ITBVI* (deltaITBVI*) did not differ significantly and correlated closely (r = 0.90; p < 0.0001). Percent changes in cardiac index (CI) as a result of volume loading (deltaCI) revealed significant correlation to deltaITBVI (r = 0.85; p < 0.0001) and to deltaITBVI* (r = 0.76; p < 0.0005). No significant correlation could be found between deltaCI and deltaEDAI or deltaCVP.

CONCLUSION

In patients undergoing cardiac surgery, determination of ITBVI* revealed close agreement with measurements derived by ITBVI. Enhancement in cardiac preload was adequately detected by ITBVI*.

Для цитирования: Reuter Daniel A, Felbinger Thomas W, Moerstedt Karl, Weis Florian, Schmidt Christian, Kilger Erich, Goetz Alwin E. Intrathoracic blood volume index measured by thermodilution for preload monitoring after cardiac surgery.. Journal of cardiothoracic and vascular anesthesia. 2002. DOI: 10.1053/jcan.2002.31064.