MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1528-1167.2007.00982.x

Медицинская библиотека · Epilepsia · 2007

Repeated intracarotid amobarbital tests.

Loddenkemper Tobias, Morris Harold H, Lineweaver Tara T, Kellinghaus Christoph

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

RATIONALE: Our goal was to determine the frequency of repeated intracarotid amobarbital test (IAT) at our center and to estimate the retest reliability of the IAT for both language and memory lateralization.

METHODS

A total of 1,249 consecutive IATs on 1,190 patients were retrospectively reviewed for repeat tests.

RESULTS

In 4% of patients the IAT was repeated in order to deliver satisfactory information on either language or memory lateralization. Reasons for repetition included obtundation and inability to test for memory lateralization, inability to test for language lateralization, no hemiparesis during first test, no aphasia during first test, atypical vessel filling, and bleeding complications from the catheter insertion site. Language lateralization was reproduced in all but one patient. Repeated memory test results were less consistent across tests, and memory lateralization was unreliable in 63% of the patients.

DISCUSSION: In spite of test limitations by a varying dose of amobarbital, crossover of amobarbital from one side to the other, testing of both hemispheres on the same day, practice effects, unblinded observers, fluctuating cooperation of the patients, and a biased sample of patients language lateralization was reproduced in all but one patient. In contrast, repeated memory test results were frequently contradictory. Memory results on IAT therefore seem much less robust than the results of language testing. Gain of reliable information versus the risks of complications and failed tests has to be considered when a patient is subjected to an IAT.

Для цитирования: Loddenkemper Tobias, Morris Harold H, Lineweaver Tara T, Kellinghaus Christoph. Repeated intracarotid amobarbital tests.. Epilepsia. 2007. DOI: 10.1111/j.1528-1167.2007.00982.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.