MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-020-71063-1

Медицинская библиотека · Scientific reports · 2020

Assessment of aPTT-based clot waveform analysis for the detection of haemostatic changes in different types of infections.

Tan Chuen Wen, Wong Wan Hui, Cheen McVin Hua Heng, Chu Yvonne Miao Hui, Lim Shan Shan, Ng Lawrence Cheng Kiat, Yeo Dillon Guo Dong, Morvil Gayathry, Lee Lai Heng, Ng Heng Joo

СтатьяПеревод в очереди

Аннотация

Infections cause varying degrees of haemostatic dysfunction which can be detected by clot waveform analysis (CWA), a global haemostatic marker. CWA has been shown to predict poor outcomes in severe infections with disseminated intravascular coagulopathy. The effect of less severe bacterial and viral infections on CWA has not been established. We hypothesized that different infections influence CWA distinctively. Patients admitted with bacterial infections, dengue and upper respiratory tract viral infections were recruited if they had an activated partial thromboplastin time (aPTT) measured on admission. APTT-based CWA was performed on Sysmex CS2100i automated analyser using Dade Actin FSL reagent. CWA parameters [(maximum velocity (min1), maximum acceleration (min2) and maximum deceleration (max2)] were compared against control patients. Infected patients (n = 101) had longer aPTT than controls (n = 112) (34.37 ± 7.72 s vs 27.80 ± 1.59 s, p < 0.001), with the mean (± SD) aPTT longest in dengue infection (n = 36) (37.99 ± 7.93 s), followed by bacterial infection (n = 52) (33.96 ± 7.33 s) and respiratory viral infection (n = 13) (29.98 ± 3.92 s). Compared to controls (min1; min2; max2) (5.53 ± 1.16%/s; 0.89 ± 0.19%/s2; 0.74 ± 0.16%/s2), bacterial infection has higher CWA results (6.92 ± 1.60%/s; 1.04 ± 0.28%/s2; 0.82 ± 0.24%/s2, all p < 0.05); dengue infection has significantly lower CWA values (3.93 ± 1.32%/s; 0.57 ± 0.17%/s2; 0.43 ± 0.14%/s2, all p < 0.001) whilst respiratory virus infection has similar results (6.19 ± 1.32%/s; 0.95 ± 0.21%/s2; 0.73 ± 0.18%/s2, all p > 0.05). CWA parameters demonstrated positive correlation with C-reactive protein levels (min1: r = 0.54, min2: r = 0.44, max2: r = 0.34; all p < 0.01). Different infections affect CWA distinctively. CWA could provide information on the haemostatic milieu triggered by infection and further studies are needed to better define its application in this area.

Для цитирования: Tan Chuen Wen, Wong Wan Hui, Cheen McVin Hua Heng, Chu Yvonne Miao Hui, Lim Shan Shan, Ng Lawrence Cheng Kiat, Yeo Dillon Guo Dong, Morvil Gayathry, Lee Lai Heng, Ng Heng Joo. Assessment of aPTT-based clot waveform analysis for the detection of haemostatic changes in different types of infections.. Scientific reports. 2020. DOI: 10.1038/s41598-020-71063-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.