Reliability of direct varicella zoster virus loop-mediated isothermal amplification method for rapid diagnosis of breakthrough varicella.

Higashimoto Yuki, Kawamura Yoshiki, Kuboshiki Ayumi, Hattori Fumihiko, Miura Hiroki, Nishimura Naoko, Ozaki Takao, Ihira Masaru, Yoshikawa Tetsushi, Nagoya VZV study group

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Since patients with breakthrough varicella (BV) have mild symptoms, clinical diagnosis is difficult. In high vaccine coverage area, as BV occurs sporadically, point of care test is required for controlling varicella outbreak. In this study, the reliability of varicella zoster virus (VZV)-loop mediated isothermal amplification (LAMP) was evaluated for the rapid diagnosis of BV.

STUDY

DESIGN

A total of 328 swab samples collected from patients with suspected varicella were analyzed. For the laboratory diagnosis of varicella, VZV real-time PCR was carried out using DNA extracted from swab samples. Swab samples without DNA extraction were used for VZV-LAMP(direct-LAMP).

RESULTS

VZV infection was diagnosed by real-time PCR in 285 cases, including 105 natural varicella cases and 180 BV cases. VZV DNA was detected in 250 (87.8%) of the 285 cases by direct-LAMP. The presence and duration of fever, number of skin eruptions, and VZV DNA load were significantly lower in BV than natural varicella. The sensitivity of direct-LAMP for the diagnosis of varicella and BV was 93.3% and 84.4%, respectively.

CONCLUSIONS

Direct LAMP was considered to be useful for rapid diagnosis of BV as it has several advantages such as low cost, ease and rapidity, as compared to real time PCR.

Для цитирования: Higashimoto Yuki, Kawamura Yoshiki, Kuboshiki Ayumi, Hattori Fumihiko, Miura Hiroki, Nishimura Naoko, Ozaki Takao, Ihira Masaru, Yoshikawa Tetsushi, Nagoya VZV study group. Reliability of direct varicella zoster virus loop-mediated isothermal amplification method for rapid diagnosis of breakthrough varicella.. Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology. 2019. DOI: 10.1016/j.jcv.2019.07.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.