Journal of neuroengineering and rehabilitation · 2020
Sensitivity to temporal parameters of intraneural tactile sensory feedback.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Valle Giacomo, Strauss Ivo, D'Anna Edoardo, Granata Giuseppe, Di Iorio Riccardo, Stieglitz Thomas, Rossini Paolo Maria, Raspopovic Stanisa, Petrini Francesco Maria, Micera Silvestro
Аннотация
BACKGROUND: Recent studies have shown that neural stimulation can be used to provide artificial sensory feedback to amputees eliciting sensations referred on the amputated hand. The temporal properties of the neural stimulation modulate aspects of evoked sensations that can be exploited in a bidirectional hand prosthesis.
METHODS: We previously collected evidence that the derivative of the amplitude of the stimulation (intra-digit temporal dynamics) allows subjects to recognize object compliance and that the time delay among stimuli injected through electrodes implanted in different nerves (inter-digit temporal distance) allows to recognize object shapes. Nevertheless, a detailed characterization of the subjects' sensitivity to variations of intra-digit temporal dynamic and inter-digit temporal distance of the intraneural tactile feedback has not been executed. An exhaustive understanding of the overall potentials and limits of intraneural stimulation to deliver sensory feedback is of paramount importance to bring this approach closer and closer to the natural situation. To this aim, here we asked two trans-radial amputees to identify stimuli with different temporal characteristics delivered to the same active site (intra-digit temporal Dynamic Recognition (DR)) or between two active sites (inter-digit Temporal distance Recognition (TR)). Finally, we compared the results achieved for (simulated) TR with conceptually similar experiments with real objects with one subject.
RESULTS: We found that the subjects were able to identify stimuli with temporal differences (perceptual thresholds) larger than 0.25 s for DR and larger than 0.125 s for TR, respectively. Moreover, we also found no statistically significant differences when the subjects were asked to identify three objects during simulated 'open-loop' TR experiments or real 'closed-loop' tests while controlling robotic hand.
CONCLUSIONS: This study is a new step towards a more detailed analysis of the overall potentials and limits of intraneural sensory feedback. A full characterization is necessary to develop more advanced prostheses capable of restoring all lost functions and of being perceived more as a natural limb by users.
METHODS: We previously collected evidence that the derivative of the amplitude of the stimulation (intra-digit temporal dynamics) allows subjects to recognize object compliance and that the time delay among stimuli injected through electrodes implanted in different nerves (inter-digit temporal distance) allows to recognize object shapes. Nevertheless, a detailed characterization of the subjects' sensitivity to variations of intra-digit temporal dynamic and inter-digit temporal distance of the intraneural tactile feedback has not been executed. An exhaustive understanding of the overall potentials and limits of intraneural stimulation to deliver sensory feedback is of paramount importance to bring this approach closer and closer to the natural situation. To this aim, here we asked two trans-radial amputees to identify stimuli with different temporal characteristics delivered to the same active site (intra-digit temporal Dynamic Recognition (DR)) or between two active sites (inter-digit Temporal distance Recognition (TR)). Finally, we compared the results achieved for (simulated) TR with conceptually similar experiments with real objects with one subject.
RESULTS: We found that the subjects were able to identify stimuli with temporal differences (perceptual thresholds) larger than 0.25 s for DR and larger than 0.125 s for TR, respectively. Moreover, we also found no statistically significant differences when the subjects were asked to identify three objects during simulated 'open-loop' TR experiments or real 'closed-loop' tests while controlling robotic hand.
CONCLUSIONS: This study is a new step towards a more detailed analysis of the overall potentials and limits of intraneural sensory feedback. A full characterization is necessary to develop more advanced prostheses capable of restoring all lost functions and of being perceived more as a natural limb by users.