MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0358764

Медицинская библиотека · PloS one · 2026

Standardization of body weight distribution using a Force-Sensitive Resistor (FSR) matrix and foot analytics.

Hussain Tassadaq, Alharbi Soltan, Tahir Ali, Saeed Mutaz Elradi S, Masud Usman

СтатьяПеревод в очереди

Аннотация

Balanced body weight distribution across both feet is essential for maintaining musculoskeletal health and minimizing postural and ambulatory issues. Conventionally foot weight distribution is measured using specialized clinical equipment which are expensive and limits routine screening. Therefore, in this work, we present a standardized foot weight distribution model having a custom 32×32 force-sensing resistor (FSR) matrix based embedded system. A total of 4,000 volunteers participated in the Physical Fitness Assessment (PFA). Of these, 2,200 who passed the musculoskeletal fitness criteria were selected for foot pressure data collection. From these data, we derived a standard weight distribution pattern across foot regions: heel (45-55%), midfoot (10-15%), metatarsals (17-27%), and toes (8-13%). These standardized weight distribution patterns are used to identify deviations associated with musculoskeletal conditions that support early personalized rehabilitation and training strategies. The proposed model is implemented on a real-time embedded system and cloud platform. The embedded system uses a K230 RISC-V processor and performs real-time data acquisition, on-board data processing, and visualization of foot weight distribution. The application running on cloud platform performs statistical analysis and applies a classical support vector machine (SVM) for classifying abnormal pressure patterns. A Convolution Neural Network (CNN) based model is developed that learns fit and un-fit foot patterns from the 32×32 pressure maps. The model results show improved detection of dysfunctional weight distribution. The CNN approach shows that AI model can perform advanced predictive analytics in gait and posture assessment. The analysis is limited to static standing posture and does not include dynamic gait assessment. The normative ranges are derived primarily from subjects up to approximately 80-90 kg, as no musculoskeletally fit participants were identified in the heavier weight groups (90-120 kg); therefore, generalization to heavier individuals requires caution and further data collection.

Для цитирования: Hussain Tassadaq, Alharbi Soltan, Tahir Ali, Saeed Mutaz Elradi S, Masud Usman. Standardization of body weight distribution using a Force-Sensitive Resistor (FSR) matrix and foot analytics.. PloS one. 2026. DOI: 10.1371/journal.pone.0358764.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.